Service and Repair Manual

19
TROUBLESHOOTING (cont.)
Torque Sensor Error
Yes
No
Sensor unplugged or
break in wiring
Yes
No
TORQUE SENSOR ERROR
TORQUE SENSOR
SHORTED
TORQUE SENSOR OPEN
Are augers
turning?
Left side
Right side
Left side
Right side
Go to motor
troubleshooting
Are augers shaft pins
damaged or missing?
Check sensor
circuit
Replace as necessary
41084 102709