Service and Repair Manual

49
SERVICE (cont.)
LAMP CORD ASSY
FIG. 45 LAMP CORD ASSY
Location:
The lamp cord assembly is located in the top center
of the auger motor cover.
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Unplug the lamp cord assembly from lamp cord
connector assembly.
3. Check for continuity across the tip of the cord as-
sembly and the housing. Continuity must not be
present when both lamps are removed.
If continuity is present as described, the cord assembly
is operating properly.
If continuity is not present as described, replace the
cord assembly.
Removal and Replacement:
1. Disconnect the lamp cord assembly from the lamp
cord connector assembly in the top of the auger
motor cover.
2. Remove the hopper cover with the lamp cord as-
sembly from the hopper.
3. Remove hopper cover liner from the hopper
cover.
4. Cut the closed splice terminals connecting lamp
cord assembly to the lamp holder/socket assembly
off.
5. Remove lamp cord assembly from hopper cover
and discard.
6. Push new lamp cord wires through the holes on
the left outside top of the hopper cover.
7. Strip the wires from the lamp holder/socket as-
sembly approximately .375”.
8. Using the two wire nuts, supplied, connect the new
lamp cord assembly to the lamp holder/socket as-
sembly wires.
9. Reinstall the hopper liner to the bottom of the hop-
per cover.
10. Reinstall the hopper cover to the hopper.
11. Plug in the new lamp cord assembly to the lamp
cord connector assembly on top of the auger mo-
tor cover.
12. Refer to Fig. 46 when reconnecting the wires.
FIG. 46 LAMP CORD WIRES
P1332
ULTRA-2 shown
41084 102709