Use and Care Manual

Page 12
Location:
The ON/OFF switch(s) are located on the front of
the hood.
Test Procedure:
1. Disconnect the brewer from the power source.
2. Viewing the switch from the back remove the white
or red wire from the upper terminal and the black
wire from the center terminal.
3. Check the voltage across the white wire or red wire
and the black wire with a voltmeter. Connect the
brewer to the power source. The indication must
be:
a) 120 volts ac for two wire 120 volt models and
three wire 120/240 volt models.
b) 200 to 240 volts ac for two wire 200 or 240 volt
models.
4. Disconnect the brewer from the power source.
If voltage is present as described, reconnect the white
or red wire and proceed to #5.
If voltage is not present as described, refer to the Wiring
Diagrams and check the brewer wiring harness.
5. With the black wire removed, remove the wire from
the lower terminal.
6. Check for continuity across the center and lower
terminal with the switch in the "ON" position.
Continuity must not be present when the switch
is in the "OFF" position.
If continuity is present as described, reconnect the
black wire to the center terminal and the remaining
wire to the lower terminal.
If continuity is not present as described, replace the
switch.
SERVICE (cont.)
ON/OFF WARMER SWITCH
FIG. 12-1 ON/OFF WARMER SWITCHES
FIG. 12-2 WARMER SWITCH TERMINALS
Removal and Replacement:
1. Remove the wires from the switch terminals.
2. Compress the clips inside the hood and gently
push the switch through the opening.
3. Push the new switch into the opening and spread
the clips to hold switch in the hood.
4. Refer to Fig.7 when reconnecting the wires.
(3) WHI to Neutral or RED to L2
(2)BLKtoL1
(1) To Warmer
WARMER SWITCH
(1) LOAD (WARMER)
(2) LINE (L1)
(3) NEUTRAL (L2)
41711.1 052009