SERVICE (cont.)
TANK HEATER SWITCH (cont.)
FIG.19-1TANKHEATERSWITCHTERMINALS
15. Set tank assembly inside the hood on mounting
brackets and secure with two #8-32 screws.
16. Reconnect the wires to the limit thermostat, tank
heater and the control thermostat. Refer to limit
thermostat, tank heater and control thermostat sec-
tions in this manual when reconnecting wires.
17. Brewers with faucet reinstall the faucet tube and
reconnect the water supply tube to the coil as-
sembly.
18. Secure the sprayhead tube to the hood using hex
nut.
19. Install sprayhead.
20. Install fill basin, inlet gasket and secure to tank lid
with tank inlet fitting.
21. Carefully install water fill tube into the back of
the fill basin.
22. Reconnect and turn on the incoming water sup-
ply.
23. Refer to Fig. 15 when reconnecting the wires.
BLKtoLimitThermostat
BLKtoTerminalBlock
(Black Insert)