ROUTINE CLEANING
Before beginning any cleaning procedure, unplug the
brewer to avoid the accidental start of a brew cycle.
Clean the pod holder, drip tray and drip tray grate after
each use, using a damp cloth and mild detergent and rinse.
With the pod holder and drip tray removed, use a damp cloth
with mild detergent to wipe the area below the pod holder
and into the drip tray area. Occasionally, wipe the outside of
the brewer with a damp cloth. (The reservoir, slide lid, pod
holder, drip tray and drip tray grate are dishwasher safe.)
PERIODIC CLEANING/DESCALING
(Recommended At Least Once a Month.)
Periodically, you should clean and descale the brewer to clear any mineral
deposits that may have accumulated due to impurities in the water source. If these
deposits are not removed, they can impair the operation of the brewer and reduce
the product life.
There are several products available specifically for descaling. We recommend
using URNEX
®
Activated Descaler or JavaClean2 Cleaner and Descaler, available
on our web site: www.bunn.com. (White vinegar can be used to descale if a
descaling product is not available.)
Follow the directions as printed on the manufacturer’s package.
1) Fill the reservoir with descaling product as described by the manufacturer’s
directions, or 32 oz. (946 ml) of white vinegar. Do not
add powder mix directly to the reservoir. Descaling
product must be mixed into a solution before it is
added to the reservoir.
2) Place an empty pod holder into the brewer. Be sure
the holder is locked into place, and set the VOLUME
CONTROL SLIDE LEVER to the maximum position.
3) Place an empty container or bowl on the drip tray grate
that will hold at least 14 oz. (414 ml) of liquid, and
press the COFFEE BREW BUTTON to start a brew cycle.
4) Once the brew cycle has finished, empty the container
and set it back onto the drip tray grate. Press the
COFFEE BREW BUTTON again to start a second brew
cycle.
5) Once the brew cycle has finished, empty the container
and the remaining solution, or vinegar from the
reservoir. Remove the pod holder; clean the reservoir
and pod holder thoroughly using a mild detergent, then
rinse.
NOTE: There is now descaling solution in the internal tank.
Follow the manufacturer’s directions if the solution must be
left in the tank for any period of time. For vinegar, allow the
solution to sit for at least two, but no more than four hours.
6) Fill the reservoir to the “MAX” line with fresh clean cold
water and place the pod holder back into the brewer.
P3028
P2958
P2908
P2963