Programming Manual

Page 9
PROGRAMMING WITH AD CARD
Using an AD CARD to load ADS:
The information is loaded into the brewer’s memory
by holding the chip area up to the brewer’s SENSING
COIL.
NOTE: Instructions to program the brewer are printed
on the AD CARD.
Procedure to program the AD:
1. Remove the funnel(s) if present.
2. Position the RECIPE CARD vertically, so that the
top end of the CHIP is beneath the (Left on Twins)
SENSING COIL (located on the underneath side of
the front display panel).
3. After a short pause the display will read CARD
CONTAIN ADS/SHOW-QUIT-SAVE.
4. To show (view) this information, select "SHOW".
The display will scroll through all of the ad on that
chip. The display will then return to CARD CONTAIN
ADS/SHOW-QUIT-SAVE.
5. If message is correct, press SAVE. The display will
read AD MESSSAGE SETUP COMPLETE. The ad is
now stored in the brewer’s memory.
6. If the ad is not correct, or it is desired to exit the
setup before the ad is loaded into the brewer’s
memory, press QUIT. The display will then return
to the MAIN SCREEN.
POSITION CARD UNDER
SENSOR COIL
SCROLLS THROUGH
COMPLETE MESSAGE
NOTE: ENABLE ADS must be
turned on in order for the newly
programmed ad message to be
displayed.
READY TO BREW
CARD CONTAIN ADS
AD MESSAGE
READY TO BREW
WATER TEMP XXX°
SHOW QUIT SAVE
SETUP COMPLETE
WATER TEMP 200°
53669 041817
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
ENABLE BREW
I
O
ENABLE BREW
I
O
To reduce the risk of electric shock,
do not remove or open cover.
No user-serviceable parts inside.
Authorized service personnel only.
Disconnect power before servicing.
WARNING