Repair manual

Page 28
PROGRAMMING - LEVEL 3
SPRAY OZ/M: ##.#
(-) DONE (+)
Allows technician to calibrate after probe and/or control board replace-
ment. Select "YES".
NOTE: Tank temperature must be within range (192° - 208° F)
Insert an accurate thermometer approximately 10˝ into tank. Adjust the
number on the right with +/- until it matches reading of thermometer.
Select "DONE"
This screen allows adjustment of the lime compensation system when
BrewLOGIC is turned on.
Range: 2 - 50. Default: 10% variation of brewed volume.
200° CAL 200°
(-) DONE (+)
The remaining screens in Level 3 are just a convenient shortcut to the
same ones used in previous levels.
LP1 LP2 OZ 4.50
(-) DONE (+)
CAL TEMPERATURE
NO SENSOR? YES
(-) DONE (+)
% LimeAdjust OFF
CALIBRATE FLOW ?
NO YES
39132 032012
VIDEO CLIP: Calibrate Temp Click - >
VIDEO CLIP: Calibrate sprayhead fl ow
rate with BrewLogic on Click - >
VIDEO CLIP: Calibrate sprayhead fl ow
rate with BrewLogic off Click - >