Repair manual

Page 40
29077.0016B 11/09 ©2008 BUNN-O-MATIC CORPORATION
SOL
BLU-14
BLU-14
"KEEP WARM" HEATER
WHI/RED
WHI
WHI
WHI
WHI
SOL
REFILL
DISPENSE
J1-1
J1-5
J1-10
#
/
.
4
2
/
,
0
#
"
/
!
2
$
BLK
BLK-14
BRN/BLK
BLK-14
WHI/GRN
WHI/GRN
WHI/BLU
WHI/BLU
YEL
WHI/VIO
VIO
BLK
WHI
CONTROL SWITCH ASSY
J2-1
J2-6
J2-10
B1
STATIC
SHIELD
D1
A3 D2 A4 D3 B2
J3-1
J3-3
BRN
BLU
WHI
GRN
LEVEL PROBE (LONG)
LEVEL PROBE (SHORT)
to
J9-1
BLK
CONTROL SWITCH ASSY CODES
2 WARMERS
ON LEFT
2 WARMERS
ON TOP
2 WARMERS
ON RIGHT
BREW STATION A3 A3 A3
LEFT FRONT A2
LEFT REAR A1
TOP FRONT A5
TOP REAR A6
RIGHT FRONT A5
RIGHT REAR A6
START BREW A4 A4 A4
LEFT HIDDEN B1 B1 B1
RIGHT HIDDEN B2 B2 B2
“DIGITAL” D1 D1 D1
“BREWER” D2 D2 D2
“CONTROL” D3 D3 D3
GRN
WHI
BLK-14
TANK HEATER
WHI-14
RELAY
100V AC
2 WIRE
SINGLE PHASE
MAIN POWER
SWITCH
Chassis Ground Earth Ground
LIMIT
THERMOSTAT
SCHEMATIC WIRING DIAGRAM AXIOM-APS
N
L1
RED
WHI
EMI
FILTER
GRN/YEL
BLK
BLK
Chassis Ground
39132 120309