ULTRA-1 ULTRA-2 PROGRAMMING MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 41047.
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor.
INTRODUCTION This equipment dispenses granita-type and cold liquid drinks on demand from separate hoppers. Operating controls are accessible only through password protection. CONTENTS Introduction & Warranty....................................................................................................... 3 Operating Controls................................................................................................................ 8 Programming.....................................................
OPERATING CONTROLS ULTRA-1 There are three of these switches that will be used for the operation of the dispenser. 1 2 3 P3932 1. switch (upper left corner of the control pad) This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and forth continously except during programming. 2. (upper right corner) This is used to turn the auger motor to AUGER ON, AUGER OFF or AUGER REFILL ON. (Refill only applicable when installed) 3.
OPERATING CONTROLS ULTRA-2 There are five of these switches that will be used for the operation of the dispenser. 1 P3677 2 3 4 5 1. switch (upper left corner of the control pad) This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and forth continously except during programming. 2. (bottom left corner) This is used to turn the left side auger motor to AUGER ON, AUGER OFF or AUGER REFILL ON.
PROGRAMMING Using the menu-driven display on the front of the dispenser, the operator has the ability to alter or modify various parameters such as beverage consistency and set day/night “ON/OFF” times. The operator is also prompted to check a variety of periodic service functions or even a step-by-step cleaning routine. There is also the opportunity to return all changes back to factory default settings. Access to most controls can be password protected to allow only qualified personnel to make changes.
PROGRAMMING THE DISPENSER During normal operations, the Date, the Time, and the Serial Number toggle back and forth continuously. The following function screens are in the order they appear from the menu display. Each screen will have instructions and procedures to program the various functions of the dispenser. HOME SCREEN Displays the TIME, DATE, SERIAL NUMBER and ASSET NUMBER which toggle back and forth continuously. 10:45:30 AM off off JAN.
MENU FUNCTION INDEX (Continued) CLEANING GUIDE ? NO YES SET THICKNESS ? NO YES TEST AUGERS ? NO YES SET DATE TIME ? NO YES PASSWORD 0 (-) NEXT (+) SET LANGUAGE ? NO YES SET NIGHT TIME (-) OFF (+) DEFROST MINUTES (-) OFF (+) PM COMPLETE ? NO YES 6 MONTH PM (-) OFF (+) DAY TO CLEAN OFF (-) NEXT (+) YES THICK ADJUST (-) NEXT (+) SWITCHES (-) ON (+) 250 L REFILL 155 (-) THRESHOLD (+) 250 R REFILL 155 (-) THRESHOLD (+) TEST REFILL ? NO YES AD MESSAGE (-) DISABLED (+) ENTER ASSET # AN000000 SET
Cleaning Guide This function leads the operator through a nine step cleaning process when answered YES (“ICE”). Depress GOURMET to display the next cleaning instruction. When entering this mode, the refrigeration system will automatically turn OFF. After step when hoppers are drained, the augers will turn OFF. Three messages will display after advancing past the last cleaning instruction: FINISH/NEXT, PLEASE WAIT, ULTRA VERSION #__.__.
Set Consistency This function allows the operator to adjust the ice consistency, or torque of each auger when answered YES (“ICE”). Two screens will appear for left and right. The operator can scroll through a range of a minimum of 1 (ULTRA) to a maximum of 16 (ICE). Factory default is 10. NOTE: ULTRA-1 models will only have one adjustment screen.
Test Augers This function tests the operation of forward and reverse of each auger motor. Left auger appears first. Press the ICE hidden switch to toggle between OFF, FORWARD and REVERSE. Press GOURMET hidden switch to repeat the operation for the right auger motor. A one minute time out will return to the Home Screen. TEST AUGERS ? NO YES LEFT AUGER TEST NEXT FORWARD LEFT AUGER TEST NEXT OFF LEFT AUGER TEST NEXT REVERSE Select NEXT to repeat process for Right Auger Test.
Password From this screen, the operator must know the password before moving on to the remaining functions. The range is from 0 - 9999 with the factory default being 0. PASSWORD (-) NEXT 0 (+) P3678 Set Language ? (Late Model Dispensers) The setting of the Set Language mode allows the operator to scroll thru a list of languages stored in the software and select one for the display messages.
Set Night Time/Set Day Time The setting of the Day/Night mode allows the dispenser to “power down” during off hours. The bottom corners displaying “ICE” will change to “CHILL” during the night mode. During the night mode, the product will be kept chilled to below 35°F. “ICE” reading will return after night mode elapses. With “OFF” representing 12:00 AM, the operator can scroll to the times desired for the night time mode to begin and end.
Preventive Maintenance Complete? This function is used to reset a reminder message Preventive Maintenance Due every six months. The machine will not shut down if service is not performed. When the service is performed and the message is answered YES (ICE), the time and date is recorded for another six months to elapse. This feature can be DISABLED by pressing (-) ULTRA hidden switch.
Day To Clean Off This function allows the operator to program a cleaning schedule from 1 to 14 days. The default screen is 0 or OFF. Selecting - or ULTRA will prompt the screen Days To Clean. Once a number of days is selected the screen will prompt two functions, CLEAN MESSAGE ONLY or CLEAN LOCKOUT. On the day selected, the display will toggle between DATE & TIME and CLEAN DUE TODAY. The dispenser will lock into night mode at midnight if “Clean Lockout” is activated.
Consistency Adjust Lock This is an option of locking the Set Consistency function by selecting + (YES) or - (NO).
Switches Enabled This function allows the operator to lockout the touch pad. Selecting + (ON) provides no time delay on switches except for the center (GOURMET) hidden switch. Selecting - (LOCKOUT) provides a five second hold to wake up the touch pad and a two minute time frame from last button pressed to make adjustments before returning to sleep mode (five second hold).
Refill Threshold (Late Model Dispensers with Refill Kit Installed only) This function allows the operator to adjust the Refill Threshold depending on the type of product being dispensed. 250 L REFILL 155 (-) THRESHOLD (+) 250 R REFILL 155 (-) THRESHOLD (+) TEST REFILL ? NO YES ACTIVATE VALVE LEFT DONE RIGHT ULTRA-1 Models only: This function will activate the Liquid Autofill function only in machines equipped with this option.
Ad Messages Enabled (Late Model Dispensers) This function allows the operator to create an AD Message that will toggle with the Home Screen messages.
Enter Asset Number This is the function to set the asset number using a range of 0 to 999999 (the factory default is 0). It is used to track the usage or service of an individual machine within a group. ENTER ASSET # AN000000 Set Password This is the function to set the password using a range of 0 to 9999 (the factory default is 0). When the password is set, the operator can only access the first four functions: Cleaning Guide, Set Consistency, Test Augers and Set Date & Time.
Restore Default? Answering YES (ICE) to this function returns the unit back to preset factory constants. 1. Set Consistency ? 8 2. Set Night Time - DISABLED 3. Set Day Time - DISABLED RESTORE DEFAULT ? 4. 6 Month PM - ON NO YES 5. Days....Off - OFF 6. Torque Adjust Lock - YES 7. Switches On - ON 8. Set Password - 0 9. R Refill Threshold - 155 10. L Refill Threshold - 155 11. Cleaning Message - RESET 12.
TEMP & TORQUE Press and hold for five seconds the ULTRA and ICE hidden switches to display the TEMP & TORQUE. The temperature of each cooling drum and the hot gas temperature will toggle back and forth. The auger torque is displayed continuously. Press and release the ULTRA and ICE hidden switches to return to HOME SCREEN. The TEMP & TORQUE mode is typically used for service.