CONPONENT ACCESS (cont)
MASTER POWER SWITCH
FIG 13 MASTER POWER SWITCH
Location:
The main power switch (FIG 13) is located un-
der the brewer in the base just behind the right front
leg on SH and GPR models and behind the front
support leg on TF models.
Test Procedure:
1. Disconnect the brewer from the power source.
2. Disconnect the wires from the power switch. With
the switch in the ON position, check for continuity
between terminals opposite each other.
There should be continuity between the two terminals
on each side when the switch is in the ON position,
no continuity when in the OFF position.
If continuity is not present as described, replace the
switch.
Removal and Replacement:
1. Disconnect the brewer from the power source.
2. Disconnect the wires from the power switch.
3. Remove the switch mounting screws from the
under the base.
4. Install new switch in trunk with the two 6-32 x ¼˝
mounting screws.
5. Connect wires to the switch terminals.