Service manual
Page 21
SERVICE (cont.)
FUNNEL SENSOR SWITCH
32248 100500
FIG. 12 FUNNEL SENSOR SWITCH
P2232
Location:
The Funnel Sensor switches are located inside the
hood and to the right of each dispense valve.
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Verify the funnel is activating the switch. Mechani-
cal adjustment may be necessary.
3. Using an ohmmeter, verify continuity when switch
is actuated and no continuity when switch is not
actuated.
P2234
FIG. 13 FUNNEL SENSOR SWITCH TERMINALS
BLK to DBC Controller J3-8
RED to DBC Controller J3-5 (Right)
YEL to DBC Controller J3-7 (Left)
Removal and Replacement:
1. Remove the two wires from the switch.
2. Remove the two #4-40 screws securing the switch
to the switch bracket and remove the switch.
3. Install the new switch to the bracket and secure
with two #4-40 screws.