S6163-AK-FSE-010 0910-LP-110-4363 REVISION 2 TECHNICAL MANUAL FOR COFFEE BREWER, BUNN-O-MATIC, MODELS C, CS, CRT, CRTF, CT, CTF, CW, CWTF, SINGLE CW AND SINGLE CWF INSTALLATION, OPERATION, AND MAINTENANCE SUPERSEDURE NOTICE: THIS MANUAL SUPERSEDES AND CANCELS S6163-AK-FSE-010, REV 1, DATED 30 SEPTEMBER 2008, AND ALL CHANGES THERETO. DISTRIBUTION STATEMENT B: DISTRIBUTION AUTHORIZED TO U. S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, 31 AUGUST 2010.
S6163-AK-FSE-010 0910-LP-110-4363 REVISION 2 TECHNICAL MANUAL FOR COFFEE BREWER, BUNN-O-MATIC, MODELS C, CS, CRT, CRTF, CT, CTF, CW, CWTF, SINGLE CW AND SINGLE CWF INSTALLATION, OPERATION, AND MAINTENANCE SUPERSEDURE NOTICE: THIS MANUAL SUPERSEDES AND CANCELS S6163-AK-FSE-010, REV 1, DATED 30 SEPTEMBER 2008, AND ALL CHANGES THERETO. DISTRIBUTION STATEMENT B: DISTRIBUTION AUTHORIZED TO U. S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, 31 AUGUST 2010.
TITLE-2 Change A @@FIpgtype@@BLANK@@!FIpgtype@@
S6163-AK-FSE-010, Rev 2 31 Aug 2010 IDENTIFYING TECHNICAL PUBLICATION SHEET FOR COMMERCIAL MANUAL This manual supersedes S6163-AK-FSE-010, Rev 1, dated 30 September 2008, and all changes thereto. 1. PURPOSE: This technical publication sheet is issued for the purpose of identifying and authorizing the following commercial manual for Navy use. Manufacturer: Bunn-O-Matic Corporation Post Office Box 3227 Springfield, Il 62708-3227 Cage 25628 Purchase Order or Contract No.: N00024-09-C-2107 Requisition No.
TITLE-2 Change A @@FIpgtype@@BLANK@@!FIpgtype@@
TABLE OF CONTENTS PART TITLE I Installation and Operating Guide II Service and Repair Manual III Illustrated Parts Catalog
TITLE-2 Change A @@FIpgtype@@BLANK@@!FIpgtype@@
PART I Installation and Operating Guide
TITLE-2 Change A @@FIpgtype@@BLANK@@!FIpgtype@@
Part I C, CT, CWTF Series Including DV, APS/TC/TS, Single CW & Twins Supercedes Operating Manuals: 10690.####; 10737.####; 10841.0000; 28182.0000; 36102.0000 INSTALLATION & OPERATING GUIDE BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at www.bunn.
Part I BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor.
INTRODUCTION Part I This equipment will brew one or two half-gallon batches of coffee simultaneously into awaiting dispensers (with just the press of a button). One side may include a hot water faucet for allied beverage use. It is only for indoor use on a sturdy counter. USER NOTICES ............................................................................................................................................ 4 ELECTRICAL REQUIREMENTS.........................................................
Part I USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. This equipment must be installed to comply with the International Plumbing Code o the International Code Council and the Food Code Manual o the Food and Drug Administration (FDA). For models installed outside the U.S.A., comply with the applicable Plumbing /Sanitation Code.
Part I ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Model 15 has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. BLK WHI RED L1 N 120V. A.C. WHI BLK L2 N BLU 120V. A.C. 208 or 240V. A.C. 120V. A.C. RED BLK L1 BLK L3 L2 230V. A.C. 230V. A.C. 230V. A.C. RED L1 200 or 230V. A.C.
Part I PLUMBING REQUIREMENTS-CURRENT SINGLES This equipment must be installed to comply with the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA). For models installed outside the U.S.A., comply with the applicable Plumbing /Sanitation Code. MODEL C: This model is completely portable and requires no attached plumbing.
PLUMBING REQUIREMENTS-CURRENT TWINS Part I TWINS These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 1⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa) . The water inlet fitting is 3⁄8" flare. 1. 2. 3. 4. 5. 6. Remove six screws securing rear utility cover (if equipped).
Part I PLUMBING REQUIREMENTS-EARLY SINGLES This equipment must be installed to comply with the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA). For models installed outside the U.S.A., comply with the applicable Plumbing /Sanitation Code. MODEL C: This model is completely portable and requires no attached plumbing.
PLUMBING REQUIREMENTS-EARLY TWINS Part I TWINS These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 1⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa) . The water inlet fitting is 3⁄8" flare. TWINS 1. 2. 3. 4. 5. 6. Remove six screws securing rear utility cover (if equipped).
Part I INITIAL SET-UP CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. 2. 3. Insert an empty funnel into the funnel rails. Place an empty dispenser under the funnel. Place the heater switch at the rear of the brewer in the “OFF” lower position and connect the brewer to the power source. 4. Fill the tank with water as directed: 4A.
Part I ADJUSTING BREW VOLUMES CAUTION - Disconnect the power source from the brewer prior to the removal of any panel for the replacement or adjustment of any component. NOTE: Prior to setting or modifying batch sizes, check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server are in place. 1. Modifying batch sizes. To modify a batch volume, first check that the SET/LOCK switch is in the "SET" position on the circuit board. To increase a batch size.
Part I OPERATING CONTROLS ON/LOWER SWITCH Placing the "ON/LOWER" switch in the "OFF" (lower) position stops brewing. Stopping a brew cycle after it has been started, will not stop the flow of water into the funnel until the tank siphons down to its proper level. Placing the switch in the "ON" (upper) position enables the brew circuit and on all (except APS/TC models) supplies power to the brew station warmer. START SWITCH Momentarily pressing and releasing the switch starts a brew cycle.
Part I OPERATING CONTROLS MASTER ON/OFF SWITCH(S) The master ON/OFF switch disables power the entire brewer (including tank heaters). NOTE – TWINS with 2 power cords will have 2 power switches, (one left, one right). TANK HEATER ON/OFF SWITCH(S) The tank heater ON/OFF switch disables power to the tank heater circuits only. Power to brew timer and warmer circuits are not affected. All Twins have 2 tank heater switches. NOTE: Leaving the tank heater switch(s) off will result in brewing with cold water.
Part I 1. 2. 3. 4. 5. 6. COFFEE BREWING Insert a BUNN® filter into the funnel. Pour the fresh coffee into the filter and level the bed of grounds by gently shaking. Slide the funnel into the funnel rails. Place an empty dispenser beneath the funnel. Place the "ON/OFF" switch in the "ON" upper position. Momentarily press and release the start switch. When brewing is completed, simply discard the grounds and filter.
Part I CLEANING 1. The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. Use care when cleaning around the heater switch with a cloth, so as not to accidentally turn off the tank heater! 2. Clean out the sprayhead holes. A properly cleaned sprayhead will leave a dimple in the bed of coffee grounds for each hole. Example: 6 holes = 6 dimples. FIG 15-1/2 3.
Part I TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • • • • • • • Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. All electronic components have 120 volt ac and low voltage dc potential on their terminals.
Part I TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Spitting or excessive steaming 1. Lime Build-up (A) Use deliming spring. (B) Clean sprayhead. (Page 11) Dripping from sprayhead 1. Syphon System The brewer must be level or slightly lower in front to syphon properly. Brew cycle starts when ON/ LOWER Switch is turned on. Auxiliary brew start switch on TWINS inadvertently activated. Move objects away from brewer. Weak beverage 1.
TITLE-2 Change A @@FIpgtype@@BLANK@@!FIpgtype@@
PART II Service and Repair Manual
TITLE-2 Change A @@FIpgtype@@BLANK@@!FIpgtype@@
Part II C, CS, CT, CWTF, CRT, CRTF Series Including DV, MV, APS/TC/TS, Single CW & Twins Supercedes Service Manual: 41711.0000 SERVICE & REPAIR MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 41711.
Part II BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor.
Part II Contents Trouble Shooting.............................................................................................................. 4 Component Access ........................................................................................................ 10 Control Thermostat ........................................................................................................ 10 Electronic Thermostat ...........................................................................................
Part II TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • • • • • • • Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. All electronic components have 120 volt ac and low voltage dc potential on their terminals.
Part II TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Brew cycle will not start (cont.) 3. ON/OFF Switch Refer to Service - ON/OFF Switch for testing. 4. Start Switch Refer to Service - Start Switch for testing procedures. 5. Timer Refer to Service - Timer for testing procedures. 6. Solenoid Valve Refer to Service - Solenoid Valve for testing procedures. 7. Water strainer/flow control (.222 GPM) Early models (A) Direction of flow arrow must be pointing towards brewer.
Part II TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Inconsistent beverage level in dispenser 1. Strainer /flow control (.222 GPM) Early models. (A) Direction of flow arrow must be pointing towards the brewer. (B) Remove the strainer/flow control and check for obstruction. Clear or replace. Consistently low beverage level in the dispenser 2. Syphon System The brewer must be level or slightly lower in front to syphon properly. 3.
Part II TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Spitting or excessive steaming (cont.) 2. Control Thermostat Refer to Service - Control Thermostat for testing procedures. Dripping from sprayhead 1. Syphon System The brewer must be level or slightly lower in front to syphon properly. 2. Lime Build-up CAUTION - Tank and tank components should be delimed regularly depending on local water conditions.
Part II TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Weak beverage 1. Filter Type BUNN® paper filters must be used for proper extraction. 2. Coffee Grind A fine or drip grind must be used for proper extraction. 3. Sprayhead A six-hole stainless steel sprayhead must be used for proper extraction. 4. Funnel Loading The BUNN® paper filter must be centered in the funnel and the bed of ground leveled by gentle shaking. 5.
TROUBLESHOOTING (cont.) PROBLEM Part II PROBABLE CAUSE REMEDY Brewer is making unusal noises (cont.) 4. Tank Heater Remove and clean lime off the tank heater. Low beverage serving temperature 1. Warmer Refer to Service - Warmer element for testing procedures. 2. ON/OFF Switch Refer to Service - ON/OFF Switch for testing procedures. Page 9 41711.
Part II SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. The brewer should be unplugged when servicing, except when electrical tests are required and the test procedure specifically states to plug-in the brewer.
Part II SERVICE (cont.) OPTIONAL ELECTRONIC THERMOSTAT (ERT): The ERT is located inside the trunk on the upper left side of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Gently remove the temperature sensor and grommet from the tank. 3. Check voltage across the blue wire from limit thermostat and the white wire at the terminal block. Connect the brewer to the power source. The indication must be: 120Vac.
Part II SERVICE (cont.) ON/OFF WARMER SWITCH Removal and Replacement: 1. Remove the wires from the switch terminals. 2. Compress the clips inside the hood and gently push the switch through the opening. 3. Push the new switch into the opening and spread the clips to hold switch in the hood. 4. Refer to Fig.7 when reconnecting the wires. FIG. 12-1 ON/OFF WARMER SWITCHES Location: The ON/OFF switch(s) are located on the front of the hood. (3) WHI to Neutral or RED to L2 (2) BLK to L1 Test Procedure: 1.
Part II SERVICE (cont.) START SWITCHES Test Procedure: 1. Disconnect the brewer from the power supply. 2. Disconnect the blue wire and the white/red wire from the switch terminals. 3. Check for continuity across the two terminals on the switch when it is held in the "pressed-in" position. Continuity must not be present across these terminals in the released position. CT SERIES CRT/CRTF If continuity is present as described, reconnect the blue wire and the white/red to the switch terminals.
Part II SERVICE (cont.) SOLENOID VALVES 6. Check the solenoid valve for coil action. Connect the brewer to the power source. With "ON/OFF" switch in the "ON' upper position press start switch and listen carefully in the vicinity of the solenoid valve for a" clicking" sound as the coil magnet attracts. 7. Disconnect the brewer from the power source.
Part II SERVICE (cont.) SOLENOID VALVES Disassembly: 1. Use of the basin wrench 01060.0000 is recommended for disassembly of early style valves as illustrated below. 2. Disconnect from power source and turn off the water supply to the brewer. 3. Disconnect the water lines to and from the solenoid valve. 4. Remove the two #8-32 screws securing the solenoid mounting bracket to the component bracket. Remove solenoid bracket and solenoid valve as an assembly. 5.
Part II SERVICE (cont.) FILL BASIN TANK HEATER FIG. 16-1 TANK HEATER FIG. 16-2 TANK HEATER Disassembly: 1. Use of the basin wrench 01060.0000 is recommended for removal of the fill basin. 2. Disconnect from power source and turn off the water supply to the brewer. 3. Remove top cover. 4. Use the basin wrench (as shown above) turning counterclockwise to remove inlet fitting. 5. Lift basin off of the tank inlet. 6. Use new inlet gasket when reinstalling.
Part II SERVICE (cont.) TANK HEATER (Cont.) HEATER 1800W-120V 1850W-220V 3500W-200V 3500W-240V RESISTANCE 7.40 - 8.70 24.40 -28.40 10.70 15.36 -12.36 -17.90 TERMINAL TO SHEATH - INFINITE (OPEN) FIG. 17-1 TANK HEATER RESISTANCE If resistance is present as described, reconnect the wires, the tank heater is ok. If resistance is not present as described, replace the tank heater. NOTE- If any resistance is read between sheath and either terminal, remove and inspect heater for cracks in the sheath. 11.
Part II SERVICE (cont.) TANK HEATER SWITCH 5. With the tank heater switch in the "ON" upper position, check for continuity between the black wire removed from the limit thermostat and the black insert on the terminal block. Continuity should not be present in the "OFF" lower position. If continuity is present as described, the tank heater switch is operating properly. If continuity is not present as described, replace the tank heater switch.
Part II SERVICE (cont.) TANK HEATER SWITCH (cont.) 15. Set tank assembly inside the hood on mounting brackets and secure with two #8-32 screws. 16. Reconnect the wires to the limit thermostat, tank heater and the control thermostat. Refer to limit thermostat, tank heater and control thermostat sections in this manual when reconnecting wires. 17. Brewers with faucet reinstall the faucet tube and reconnect the water supply tube to the coil assembly. 18. Secure the sprayhead tube to the hood using hex nut.
Part II SERVICE (cont.) THERMAL CUT-OFF (Brewers W/Faucet) Removal and Replacement: 1. Disconnect both ends of the TCO. 2. Install new thermal cut-off. 3. Refer to Fig. 17 when reconnecting wires. Thermal Cut-Off from Tank Heater to BLK Lead from Control Thermostat WHI or RED to Terminal Block Fig. 20-1 THERMAL CUT-OFF Location: The thermal cut-off (TCO) is a thermal fuse located above the tank lid, connected to the tank heater. NOTE: Installed only on tanks with coil faucet.
Part II SERVICE (cont.) COIL/FAUCET Location: The coil for the faucet is located in the tank. Operation: Water inside the coil is separate from the brewing water and is always under line pressure. Brewing water in the tank heats the submerged coil. Use of a coil faucet during a brew cycle will not cause short potting, but is limited to 8-10 ounces of hot water before the cooler water is passed through coil. Removal and Replacement: 1. Disconnect the brewer from the power and water sources. 2.
Part II SERVICE (cont.) LIMIT THERMOSTAT If continuity is present as described, the limit thermostat is operating properly. If continuity is not present as described, replace the limit thermostat. Removal and Replacement: 1. Remove all wires from limit thermostat terminals. 2. Carefully slide the limit thermostat out from under the retaining clip and remove limit thermostat. 3. Carefully slide the new limit thermostat into the retaining clip. 4. Refer to the Fig. 5 when reconnecting the wires.
Part II contact terminals. Connect the brewer to the power source. With the "ON/OFF" switch in the "ON" position and the start switch pressed and released, check for continuity across relay terminals. 7. Disconnect the brewer from the power source. RECOVERY BOOSTER RELAY (OPTIONAL) If continuity is present as described, reconnect the blue and black wires to the relay contact terminals. If continuity is not present as described replace the relay. B = COIL to TIMER 6-9 = N.O.
Part II SERVICE (cont.) TIMER (Early Models) To Main Wiring Harness To Solenoid Valve EARLY STYLE FIG. 24-1 TIMER TERMINALS Location: The timer is located inside the front of the trunk on the upper right side of component bracket. Test Procedure. 1. Disconnect the brewer from the power source. 2. Disconnect the polarized, three pin connector from the brewer wiring harness. 3.
Part II SERVICE (cont.) FRESHNESS TIMER (Early Models) If voltage is present as described, proceed to #4. If voltage is not present as described, refer to the Wiring Diagrams and check the brewer wiring harness. 4. Check the voltage across the T3 and T4 (white/ orange and white/blue wires) of the fresh timer with a voltmeter when the "ON/OFF" switch is in the "ON" position (upper) and start switch pressed. Connect the brewer to the power source.
Part II SERVICE (cont.) DIGITAL BREW TIMER (Late Models) 4. With a voltmeter, check the output voltage across terminals TL2 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source and press the "START" switch. The indication must be as follows: a) 120 volts ac for two wire 120 volt models and three wire 120/240 volt models. b) 200 to 240 volts ac for two wire 200 volt or 240 volt models. If voltage is present as described, the timer is operating properly.
Part II SERVICE (cont.) DIGITAL BREW TIMER (Late Models)(cont.) Timer Setting: NOTE: Prior to setting or modifying volumes, check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server are in place. NOTE: All volume settings must be done with the sprayhead installed. 1. Modifying brew volumes. To modify a brew volume, first check that the SET/LOCK switch is in the “SET” position on the circuit board.
Part II SERVICE (cont.) WARMER ELEMENT(S) 4. Check the resistance across the two terminals on the warmer element. NOTE: There should be no resistance reading between the heater sheath and either terminal. Refer to the following chart. If resistance is to specification, reconnect the two wires to the warmer element. If resistance is not to specification, replace the warmer element. FIG. 28-1 WARMER ELEMENTS Location: The warmer element(s) is located under the warmer plate. Test Procedures: 1.
Part II SCHEMATIC WIRING DIAGRAM CRT5, & CRTF5 L1 HEATER SWITCH BLK LIMIT THERMOSTAT BLK BLU SWITCH AND THERMOSTAT N GREEN (FAUCET OPTION ONLY) THERMAL CUT-OFF TANK HEATER BLK L2 WHI (MODEL 20) RED (MODEL 35) WHI WHI "KEEP WARM" HEATER ON/OFF SWITCH WHI WHI WHI/RED BLK LOWER CENTER WARMER START SWITCH WHI/RED BLU SOL WHI/RED WHI/BLU T1 T5 T3 BREW TIMER ON/OFF SWITCH BLK T4 T2 WHI/GRN WHI WHI YEL LEFT FRONT WARMER ON/OFF SWITCH WHI WHI WHI/VIO BLK LEFT REAR WARMER ON/OFF SWIT
Part II SCHEMATIC WIRING DIAGRAM CRT5A, & CRTF5A L1 L2 GRN/YEL HEATER SWITCH BLK LIMIT THERMOSTAT BLU BLK (MODEL CRTF5A ONLY) THERMAL CUT-OFF BLK SWITCH AND THERMOSTAT TANK HEATER WHI RED WHI "KEEP WARM" HEATER ON/OFF SWITCH RED WHI/RED BLK RED LOWER CENTER WARMER START SWITCH WHI/RED SOL BLU WHI/RED WHI/BLU T1 T5 T3 T4 BREW T2 TIMER ON/OFF SWITCH BLK WHI/GRN RED RED YEL LEFT FRONT WARMER ON/OFF SWITCH RED RED WHI/VIO BLK LEFT REAR WARMER ON/OFF SWITCH BLK RED BRN/BLK RIG
Part II SCHEMATIC WIRING DIAGRAM CRT5B, & CRTF5B L1 L2 GREEN HEATER SWITCH BLK LIMIT THERMOSTAT BLU BLK (MODEL CRTF5B ONLY) THERMAL CUT-OFF BLK SWITCH AND THERMOSTAT TANK HEATER ON/OFF SWITCH BLK WHI WHI WHI/RED WHI LOWER CENTER WARMER START SWITCH WHI/RED SOL BLU WHI/RED WHI/BLU T1 T5 T3 T4 BREW T2 TIMER ON/OFF SWITCH WHI/GRN WHI WHI YEL BLK LEFT FRONT WARMER ON/OFF SWITCH BLK WHI WHI WHI/VIO LEFT REAR WARMER ON/OFF SWITCH BLK WHI BRN/BLK RIGHT FRONT WARMER ON/OFF SWITCH BLK
Part II RED Model 35 WHI Model 20 WHI Model 15 & 35 MAIN ON/OFF SWITCH (Late 20 & 35 Models only) BLK Model 20 & 35 READY INDICATOR BLU BLK HEATER SWITCH LIMIT THERMOSTAT BLK BLK SW.
Part II SCHEMATIC WIRING DIAGRAM CW-TS & CW-APS ERT THERMOSTAT SWITCH GRN TAN L1 E.R.T ASSY.
Part II SCHEMATIC WIRING DIAGRAM FOR CWT-APS MV, CWTF-APS MV, CWTF-TS MV, CWTF-TSR MV Page 34 41711.
Part II Page 35 41711.
Part II Page 36 41711.
Part II Page 37 41711.
Part II BLK Page 38 41711.
Part II Page 39 41711.
Part II GRN LT. READY INDICATOR BLK BLK BLU LT. SW. & THERMOSTAT BLU LT.LIMIT THERMOSTAT SW1 MAIN ON/OFF SWITCH (Late Models only) BLK (FAUCET) THERMAL SAFETY FUSE BLK RED BLK LEFT TANK HEATER BLK RED WHI WHI LEFT "KEEP WARM" HEATER RT. READY INDICATOR RED BLK BLK BLU BLK BLK RT. SW. & THERMOSTAT BLU RT.
Part II GRN LT. READY INDICATOR BLK BLK BLU LT. SW. & THERMOSTAT BLU LT.LIMIT THERMOSTAT SW1 MAIN ON/OFF SWITCH (Late Models only) BLK (FAUCET) THERMAL SAFETY FUSE BLK RED BLK LEFT TANK HEATER BLK RED WHI WHI LEFT "KEEP WARM" HEATER RT. READY INDICATOR BLK BLK BLU RT. SW. & THERMOSTAT BLU RT.
Part II SCHEMATIC WIRING DIAGRAM CWTFA TWIN 2/2 & 4/2 L1 LEFT TANK HEATER BLK L3 RED LT. SW. & THERMOSTAT BLU (FAUCET) THERMAL SAFETY FUSE BLK BLK L2 GRN/YEL LT. READY INDICATOR LT. LIMIT THERMOSTAT BLU SW1 BLU BLU RED WHI WHI LEFT "KEEP WARM" HEATER RT. READY INDICATOR BLK BLK BLK RIGHT TANK HEATER RED RT. SW. & THERMOSTAT BLU BLK BLK RT.
Part II SCHEMATIC WIRING DIAGRAM CWTFA & CWTFB TWIN 2/2 & 4/2 L1 L2 LT. READY INDICATOR RED BLK BLK (FAUCET) THERMAL FUSE BLK LT. SW. & THERMOSTAT BLU LT.LIMIT THERMOSTAT SW1 GRN/YEL BLK BLU BLK LEFT TANK HEATER RED RIGHT TANK HEATER RED RT. READY INDICATOR RED BLK BLK BLK RT. SW. & THERMOSTAT BLU RT.
Part II SCHEMATIC WIRING DIAGRAM CWTFA 2/2 TWIN, CWTFA 4/2 TWIN & CWTFA TWIN-APS GRN/YEL LT. READY INDICATOR BLK SW1 BLK BLK BLK BLU LT. LIMIT THERMOSTAT L2 BLK LT. SW. & THERMOSTAT LEFT TANK HEATER BLK BLU LEFT "KEEP WARM" HEATER WHI (FAUCET) THERMAL SAFETY FUSE BLK L1 RED WHI RT. READY INDICATOR RIGHT TANK HEATER BLK BLK RT. SW. & THERMOSTAT BLU BLK BLK BLK RT.
Part II SCHEMATIC WIRING DIAGRAM CWTFA TWIN-APS CE L1 LT. READY INDICATOR BLK LT. SW. & THERMOSTAT SW1 BLK BLU NC BLK BLU RED L2 GRN/YEL LT. TANK HEATER BLK LT. LIMIT THERMOSTAT RED RED NC BLK WHI LEFT "KEEP WARM" HEATER WHI LT. READY INDICATOR BLK LT. SW. & THERMOSTAT SW2 BLK BLU NC BLK BLU RED RT. TANK HEATER BLK RT.
Part II L1 LT. READY INDICATOR BLU BLK BLK MAIN ON/OFF SWITCH (Late Models only) BLK (FAUCET) THERMAL SAFETY FUSE LT. SW. & THERMOSTAT LT.LIMIT THERMOSTAT SW1 BLU BLK BLK LEFT TANK HEATER BLK WHI RED BLK WHI LEFT "KEEP WARM" HEATER BLK RT. SW. & THERMOSTAT RT. LIMIT THERMOSTAT BLK RED WHI RT.
Part II MAIN ON/OFF SWITCH (Late 20 & 35 Models only) BLK-14 HEATER SWITCH BLK LIMIT THERMOSTAT BLK BLU SW.
Part II SCHEMATIC WIRING DIAGRAM CWTB L1 BLU HEATER SWITCH BLK LIMIT THERMOSTAT BLK L2 GRN/YEL READY BLK SW. & THERMOSTAT (FAUCET OPTION ONLY) THERMAL FUSE BLK BLU BLK TANK HEATER RED ON/OFF SWITCH RED 3 BLK 2 1 WHI/RED WHI/RED RED LOWER WARMER OPTIONAL AUTOMATIC BREW CIRCUIT START SWITCH BLU WHI/RED P1 BLU/BLK P3 WHI/RED BLK P1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR.
Part II SCHEMATIC WIRING DIAGRAM CWTA L1 BLU HEATER SWITCH BLK LIMIT THERMOSTAT ON/OFF SWITCH (FAUCET OPTION ONLY) THERMAL FUSE BLK SW. & THERMOSTAT BLK BLU BLK L2 GRN/YEL READY TANK HEATER BLK RED WHI WHI "KEEP WARM" RED 3 BLK 2 1 WHI/RED WHI/RED RED LOWER WARMER OPTIONAL AUTOMATIC BREW CIRCUIT START SWITCH BLU WHI/RED P1 P3 WHI/RED SOL BLU/BLK BLK P1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR.
Part II SCHEMATIC WIRING DIAGRAM CWTA - CE READY INDICATOR BLU BLK L1 HEATER SWITCH LIMIT THERMOSTAT BLK SW. & THERMOSTAT GRN/YEL L2 THERMAL FUSE BLK BLK BLU THERMAL FUSE RED RED TANK HEATER BLK RED "KEEP WARM" HEATER WHI WHI BLK RED BLK ON/OFF SWITCH LOWER WARMER WHI/RED WHI/RED RED SOL OPTIONAL GRINDER INTERFACE BATCH SELECTION SWITCH 1 2 3 BREW 4 TIMER 5 P1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR.
Part II 20 AMP T1 Page 51 T5 T3 T4 T2 41711.
Part II GREEN BLK Model 15 SCHEMATIC WIRING DIAGRAM CWTF, CWTFB NO WARMER MAIN ON/OFF SWITCH (Late 20 & 35 Models only) BLK-14 N L2 RED Model 35 WHI Model 20 WHI Model 15 & 35 BLK L1 BLK Model 20 & 35 BLU HEATER SWITCH LIMIT THERMOSTAT BLK BLK BLK (FAUCET OPTION ONLY) THERMAL FUSE SW.
Part II SCHEMATIC WIRING DIAGRAM CWTFA NO WARMER L1 READY INDICATOR BLU BLK LIMIT THERMOSTAT BLK BLU HEATER SWITCH THERMAL FUSE BLK BLK SW. & THERMOSTAT L2 GRN TANK HEATER THERMAL FUSE RED RED BLK RED BLK WHI WHI ON/OFF SWITCH BLK "KEEP WARM" HEATER RED WHI/RED WHI/ORA OPTIONAL AUTOMATIC BREW CIRCUIT START SWITCH OPTIONAL FRESH LIGHT SYSTEM GRY L.E.D. PNK BLK 4 WHI/RED INDICATOR 3 2 TIMER WHI/RED BLU P3 P1 BLU BLK BLK SOL 1 P1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR.
Part II WHI GRN N L2 RED SCHEMATIC WIRING DIAGRAM CT-DV, CTF-DV, CWT-DV & CWTF-DV BLK L1 MAIN ON/OFF SWITCH (Late Models only) BLK READY INDICATOR BLU HEATER SWITCH LIMIT THERMOSTAT BLK BLK BLK SW.
Part II WHI GRN SCHEMATIC WIRING DIAGRAM CWT, CWTF - APS, TS, TC DV N L2 RED BLK L1 MAIN ON/OFF SWITCH (Late Models only) BLK READY INDICATOR BLU HEATER SWITCH BLK LIMIT THERMOSTAT BLK BLK SW.
Part II SCHEMATIC WIRING DIAGRAM SINGLE CW L1 READY HEATER SWITCH BLK LIMIT THERMOSTAT BLK (FAUCET OPTION ONLY) THERMAL FUSE BLK BLK N GRN SW.
Part II L1 BLK GRN GRN RIGHT N L2 RED N WHI SCHEMATIC WIRING DIAGRAM CWTF TWIN 4/2 & 0/6 TWO-CIRCUIT WHI RED BLK LEFT L1 L2 READY INDICATOR TANK HEATER BLK BLK BLU WHI WHI "KEEP WARM" HEATER RED READY INDICATOR RED SW.
Part II GRN BLK BLK BLU BLU K1 N.O. RT. SW. & THERMOSTAT RT. LIMIT THERMOSTAT BLK RED BLK WHI SW2 BLK LEFT TANK HEATER BLK BLU MAIN ON/OFF SWITCH (Late Models only) (FAUCET) THERMAL FUSE LT. SW. & THERMOSTAT LT. LIMIT THERMOSTAT SW1 BLK BLU WHI LEFT "KEEP WARM" HEATER BLU BLK BLU N L2 WHI BLK L1 RED SCHEMATIC WIRING DIAGRAM CWT TWIN 2/2 & 4/2 W/RECOVERY BOOSTER BLK RIGHT TANK HEATER RED BLK K2 N.O.
Part II SCHEMATIC WIRING DIAGRAM CWTF TWIN 0/6 WITH RECOVERY BOOSTER L1 BLK BLK BLU LT. SW. & THERMOSTAT BLU BLK BLU WHI L2 BLK BLK BLU LT.LIMIT THERMOSTAT SW1 N GREEN LT. READY INDICATOR RED (FAUCET) THERMAL SAFETY FUSE BLK BLK LEFT TANK HEATER RED BLK K.1. N.O. WHI BLK RT. LIMIT THERMOSTAT BLK BLU BLU SW2 RT. SW. & THERMOSTAT BLK RT. READY INDICATOR LEFT "KEEP WARM" HEATER RED BLK BLU BLK BLU RIGHT TANK HEATER BLK RED BLK K.2. N.O.
TITLE-2 Change A @@FIpgtype@@BLANK@@!FIpgtype@@
PART III Illustrated Parts Catalog
TITLE-2 Change A @@FIpgtype@@BLANK@@!FIpgtype@@
Part III C, CT, CW, CWTF Series Including DV, MV, Pourover, APS/TC/TS, Twins & Single CW Supercedes Illustrated Parts Catalogs: 10716.####; 10789.####; 10790.0000; 10834.0000; 10895.0000; 33175.0000; 35279.0000 ILLUSTRATED PARTS CATALOG Designs, materials, weights, specifications, and dimensions for equipment or replacement parts are subject to change without notice. BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 40566.
Part III BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor.
Part III TABLE OF CONTENTS TOP Covers ............................................................................................................................................... 4 HOOD ASSEMBLIES......................................................................................................................................8 TRUNKS.......................................................................................................................................................10 BASES..........
Part III TOP COVER ASSEMBLIES-SINGLES C/CT/CWTF Series Pour in lids for earlier models 1 2 3 7 5 4 6 8 All models with brass covers/ panels are no longer available 9 11 18 14 17 12 20 21 10 19 13 15 16 Single CW P3908.
QTY. TWIN Part III TOP COVER ASSEMBLIES-SINGLES ITEM PART NO. QTY. SINGLE 1 02999.0000 - 1 Plug, SST 1.19” Dia. 2 13110.0000 - 1 Lid 3 12978.0000 - 1 Chain Assembly 4 12981.0001 - 1 Lid/Chain Kit (Includes # 2-3) 5 02722.0000 02722.0001 01319.0000 01319.0000 00912.0000 2 2 2 2 2 1 1 1 1 1 Lid, Pour-in SST Lid, Pour-in BLK SST thumbscrew # 8-32 x .75" BLK thumbscrew # 8-32 x .75" Fastener, “J” Type # 8-32 6 02763.
Part III TOP COVER ASSEMBLIES-TWINS All covers/housings include flip lids &/or decals as required. 4/2 C/CT/CWTF Series 2 APS/TC & 0/6 8 12 3 9 1 10 6 4 2/2 Rear 2/2 Front 11 7 5 P3909.
QTY. TWIN TOP COVER ASSEMBLIES-TWINS ITEM PART NO. QTY. SINGLE 1 38707.1000 38707.1003 1 1 2 24254.0001 01347.0000 1 10 Housing Assembly, SST 4/2 (Incl # 11) Screw, Truss Head #6-32 x .375" 3 38707.1001 1 - Cover Assembly SST 4/2 (Incl # 9, 10) 4 24254.0000 01347.0000 1 6 - Housing Assembly, SST 2/2 Rear (Incl # 11) Screw, Truss Head #6-32 x .375" 5 38707.1002 1 - Cover Assembly SST 2/2 Rear (Incl # 8, 10) 6 24254.0002 01347.
Part III C/CT/CWTF Series HOOD ASSEMBLIES 4 5 1 6 6 7 3 8 2 2 P3910.
ITEM PART NO. 1 13350.0008* 02308.0000 - 1 6 Housing, Hood SST (Early Style No Longer Available, Order # 2) Screw #8-32 x .375" (Hood to Trunk) 2 13350.0006 13350.0016 13350.0011 23232.0000 * 23232.0002 * 23232.0004 23232.0005 02308.0000 01303.0000 00916.0000 1 1 1 1 6 2 2 1 1 1 6 1 1 Housing, Hood SST (7.125" Narrow Funnel) CWTF, Single CW Housing, Hood BLK (7.125" Narrow Funnel) Housing, Hood SST (7.625" Wide Funnel) Housing, Hood SST (7.
Part III C/CT/CWTF Series TRUNKS Early APS 8 22 All models with receptacle and/or fuse (MV) are no longer available 24 20 APS 15 1 6 18 3 7 4 14 Standard & TC 12 10 11 1 13 12 14 5 10 11 TWIN-APS 3 19 13 6 9 2 7 18 4 21 0/6 TWIN w/ 2 cords 1 10 11 11 16 10 17 12 3 13 19 23 0/6 TWIN w/ 2 cords P3911.
QTY. TWIN TRUNKS QTY. SINGLE Part III ITEM PART NO. DESCRIPTION 1 34061.1006 34061.1000 25352.0007 34208.1002 23320.1004 34061.0013 34061.1004 26285.0000 26285.0001 26285.0002 23294.0000 23294.0002 23294.0001 1 1 1 1 1 1 1 1 1 1 1 1 1 - Trunk, SST, Trunk, BLK, Trunk, SST, Trunk, SST, Trunk, BLK, Trunk, BLK, Trunk, SST, Trunk, SST, Trunk, BLK, Trunk, SST, Trunk, SST, Trunk, BLK, Trunk, SST, 11.69" Standard 11.69" Standard 12.39" TC 18.15" APS 18.15" APS 22.
Part III C/CT/CWTF Series TRUNKS Early APS 8 22 All models with receptacle and/or fuse (MV) are no longer available 24 20 APS 15 1 6 18 3 7 4 14 Standard & TC 12 10 11 1 13 12 14 5 10 11 TWIN-APS 3 19 13 6 9 2 7 18 4 21 0/6 TWIN w/ 2 cords 1 10 11 11 16 10 17 12 3 13 19 23 0/6 TWIN w/ 2 cords P3911.
QTY. TWIN TRUNKS QTY. SINGLE Part III ITEM PART NO. DESCRIPTION 5 27929.0000 02308.0000 - 2 4 Bracket, (APS Only) Screw #8-32 x .375" 6 00656.0000 1 1 Decal, Compliance To Plumbing Code 7 00831.0000 1 1 Decal, Warning-Electrical 8 00669.0003 - 2 Plug 9 11408.1002 11408.1005 11408.1006 22730.1007 22730.1002 22730.1005 22730.1003 22730.1009 01382.0000 01382.0002 26283.1000 26283.1001 23267.1000 24249.0003 23267.1001 01315.
Part III C/CT/CWTF Series TRUNKS Early APS 8 22 All models with receptacle and/or fuse (MV) are no longer available 24 20 APS 15 1 6 18 3 7 4 14 Standard & TC 12 10 11 1 13 12 14 5 10 11 TWIN-APS 3 19 13 6 9 2 7 18 4 21 0/6 TWIN w/ 2 cords 1 10 11 11 16 10 17 12 3 13 19 23 0/6 TWIN w/ 2 cords P3911.
QTY. TWIN TRUNKS QTY. SINGLE Part III ITEM PART NO. 17 12104.0000 1 - Decal, Warning-Power Supply (Brewers with two Power Cords Only) 18 38820.0000 01308.0002 01308.0003 1 2 2 1 2 2 Plate, Switch Cover (Models w/out Power Switch) Screw SST #6-32 x .25" Screw BLK #6-32 x .25" 19 24213.0000 1 - Decal, Tank Heater (Includes Left & Right Decals) 20 10165.0000 10447.0000 24540.0000 26225.
Part III C/CT/CWTF Series BASES 4 12 3 1 7 2 10 8 5 6 9 1 Lower Warmer APS/TC/TS 3 Lower Warmers 12 10 13 12 11 Single CW 27 10 28 8 14 23 6 15 5 TWIN-APS/TC 17 3 TWIN-0/6 19 18 26 16 19 6 11 15 5 20 21 17 11 22 24 6 15 23 25 TWIN-2/2 & 4/2 5 P3912.
QTY. TWIN BASES QTY. SINGLE Part III ITEM PART NO. DESCRIPTION 1 23321.0000 23321.0001 23321.0002 23321.0003 23321.0004 - 1 1 1 1 1 Base W/decals, Sst (Includes Item 6) Aps Base W/decals, Sst (Includes Item 6) Ts Base W/decals, Sst (Includes Item 6) Aps (Ce) Base W/decals, Sst (Includes Item 6) Ts (Ce) Base W/decals, Blk (Includes Item 6) Aps 2 22999.0000 02332.0002 - 1 8 Plate, Base APS/TC/TS Screw, Hex-crimptite #6-32 X .375” 3 00754.0001 4 2 Locator 4 22740.
Part III C/CT/CWTF Series BASES 4 12 3 1 7 2 10 8 5 6 9 1 Lower Warmer APS/TC/TS 3 Lower Warmers 12 10 13 12 11 Single CW 27 10 28 8 14 23 6 15 5 TWIN-APS/TC 17 3 TWIN-0/6 19 18 26 16 19 6 11 15 5 20 21 17 11 22 24 6 15 23 25 TWIN-2/2 & 4/2 5 P3912.
BASES QTY. SINGLE Part III ITEM PART NO. QTY. TWIN 20 24253.0001 24253.0002 02308.0000 1 1 12 - Base W/decals, Sst (Includes # 10 & 21) Twin 0/6 Base W/decals, Blk (Includes # 10 & 21) Twin 0/6 Screw, #8-32 X .375” 21 24230.0000 2 1 Decal, Red Decorative Stripe 22 23329.0000 02332.0002 1 18 - Plate, Base, Twin 0/6 Screw, Hex-crimptite #6-32 X .375” 23 00511.1000 13255.0005 26528.0001 1 Set 1 Set - 4 Legs, 4” Adjustable, Satin Nickel, .
Part III C/CT/CWTF Series TANK AND COMPONENTS 15 8 11 9 10 22 21 10 23 4 11 16 3 17 4 12 14 19 7 20 Multi-Volt 18 6 13 Dual-Volt 1320W 5 4 1 1800W 1800W 2 1320W 3500W P3913.
QTY. TWIN Part III TANK AND COMPONENTS ITEM PART NO. QTY. SINGLE DESCRIPTION 1 04118.0000 20201.3000 01315.0000 00912.0000 2 4 4 1 1 2 2 Tank Tank (Single CW) Screw #8-32 x .375˝ TRSHD Clip, J-Type #8-32 2 04260.0000 01927.0000 2 2 1 1 Blanket Warmer 50W, 120V Blanket Warmer 50W, 220V 3 29329.1000 2 1 Thermostat, Limit 4 25158.0000 25158.0001 25158.0002 25158.0004 00908.
Part III C/CT/CWTF Series TANK AND COMPONENTS 15 8 11 9 10 22 21 10 23 4 11 16 3 17 4 12 14 19 7 20 Multi-Volt 18 6 13 Dual-Volt 1320W 5 4 1 1800W 1800W 2 1320W 3500W P3913.
QTY. TWIN Part III TANK AND COMPONENTS ITEM PART NO. QTY. SINGLE DESCRIPTION 20 01082.0000 01082.1000 01082.0004 01082.0005 01082.0007 2 # 2 2 2 1 # 1 1 1 Sprayhead, 6-Hole (6-.078 Standard) 3 Pack, 6-Hole (6-.078 Standard) Sprayhead, 5-Hole (5-.070 Optional) Sprayhead, 5-Hole (5-.057 Optional) Sprayhead, 1-Hole (1-.182 Pouch-Pack Funnel) 21 28242.0000 - 1 Lead, Electrical WHI (Tank Heater Jumper) 22 28173.
Part III C/CT/CWTF Series FILL BASIN AND LINES 7 5 13 9 14 5 13 12 Second Style Fitting 15 2 1 11 First Style 5 2 4 1 3 7 8 9 6 10 8 P3914 24 40566 101507
QTY. TWIN FILL BASIN AND LINES QTY. SINGLE Part III ITEM PART NO. DESCRIPTION 1 04270.0002 04270.0000 2 - 1 1 Fill Basin (Automatics) Fill Basin (Pour Overs) 2 27514.0000 11424.0000 2 - 1 1 Plate, Splash Guard (Automatics and Early Model Pour Overs) Plate, Splash Guard (Late Model Pour Overs) 3 01201.0000 2 1 Gasket, Tank Inlet 4 12928.0000 2 1 Grommet, Pour-In Basin (Automatics and Early Model Pour Overs) 5 01200.0000 32063.0000 01212.0000 01212.
Part III MANIFOLD AND LINES - LATER TWINS C/CT/CWTF Series 9 7 6 5 3 4 2 1 5 6 7 8 P4036.
QTY. TWIN MANIFOLD AND LINES - LATER TWINS ITEM PART NO. QTY. SINGLE 1 33643.0000 2 - Tube, Manifold to Bulkhead 2 00436.0001 2 - Union, Tn Pl-.250 Flare Male 3 41268.0000* 1 - Tube Assy, Manifold (Not available, order item 4) 4 41267.0000 1 - Tube Assy, Manifold (Late Models) 5 00459.0000 3 - Fitting, Bulkhead .250˝ Flare 6 01532.0000 3 - Lockwasher, Internal Tooth .438˝ I.D. 7 00463.0000 3 - Nut, Hex .438˝-20 8 41281.
Part III C/CT/CWTF Series STRAINER/FLOW CONTROL AND LINES - EARLY TWINS 9 19 14 11 20 10 16 9 1 21 17 18 1 15 22 20 13 15 9 10 EARLY MODELS 11 1 8 9 10 11 12 2 3 4 5 6 7 P3915.
STRAINER/FLOW CONTROL AND LINES - EARLY TWINS QTY. TWIN QTY. SINGLE Part III ITEM PART NO. DESCRIPTION 1 22300.0222 2 1 Strainer/Flow Control Assy .222 GPM (Includes # 2 - 7) 2 22249.0000 2 1 Cap 3 23721.0000 2 1 Screen 4 22312.0000* 2 1 Housing (Order # 1) 5 20526.1222 2 1 Flow Washer/Gasket Set, .222 GPM (Includes # 6) 6 01155.0000 2 1 Gasket 7 01154.0000 2 1 Fitting, Flow Control Outlet 8 33643.
Part III C/CT/CWTF Series MANIFOLD ASSEMBLIES - LATER SINGLES W/O Faucet (Optional) 1 10 2 9 8 3 4 7 6 5 P4037 30 40566 040109
MANIFOLD ASSEMBLIES - LATER SINGLES ITEM PART NO. QTY. TWIN QTY. SINGLE 1 00310.0000 - 1 Tube Assy. 2 00459.0001 - 2 Fitting, Bulkhead .250˝ Flare 3 01532.0000 - 2 Lockwasher, Internal Tooth .438˝ I.D. 4 00463.0000 - 2 Nut, Hex .438˝-20 5 41252.0000 - 1 Tube, Bulkhead to Solenoid 6 21814.0016 - 1 Tube 7 20690.0000 - 1 Tube Assy, Bulkhead to Coil 8 20577.0001 - 1 Tee .25˝ Flare 9 41257.0000 - 1 Tube Assy, 10 41254.
Part III C/CT/CWTF Series STRAINER/FLOW CONTROL - SECOND STYLE SINGLES W/O Faucet 2 3 8 1 1 19 4 5 6 15 7 18 17 1 16 13 9 10 11 14 12 P3916 32 40566 081508
STRAINER/FLOW CONTROL - SECOND STYLE SINGLES ITEM PART NO. QTY. TWIN QTY. SINGLE 1 22300.0222 2 1 Strainer/Flow Control Assy .222 GPM (Includes # 2 - 7) 2 22249.0000 2 1 Cap 3 23721.0000 2 1 Screen 4 22312.0000* 2 1 Housing (Order # 1) 5 01155.0000 2 1 Gasket 6 20526.1222 2 1 Flow Washer/Gasket Set, .222 GPM (Includes # 5) 7 01154.0000 2 1 Fitting, Flow Control Outlet 8 00310.0000 - 1 Tube, Strainer/Flow Control to Bulkhead 9 00459.
Part III STRAINER/FLOW CONTROL - FIRST STYLE SINGLES 15 C/CT/CWTF Series 14 13 13 16 10 16 20 12 9 5 3 17 11 6 7 2 18 8 19 FIRST TYPE W/FAUCET 21 FIRST TYPE W/O FAUCET SECOND TYPE W/FAUCET 2 24 3 22 16 23 27 1 4 5 6 9 7 10 11 26 25 29 Internal Strainer/Flow Control 6 30 28 P3917 34 40566 101507
STRAINER/FLOW CONTROL - FIRST STYLE SINGLES QTY. TWIN QTY. SINGLE Part III ITEM PART NO. DESCRIPTION 1 22300.0222 2 1 Strainer/Flow Control Assy. .222 GPM (Includes # 2 - 7) 2 22249.0000 2 1 Cap 3 23721.0000 2 1 Screen 4 22312.0000* 2 1 Housing (Order # 1) 5 01155.0000 2 1 Gasket 6 20526.1222 2 1 Flow Washer/Gasket Set, .222 GPM (Includes # 5) 7 01154.0000 2 1 Fitting, Flow Control Outlet 8 00310.0000 - 1 Tube Assy. Strainer/Flow Control to Bulkhead 9 23820.
Part III C/CT/CWTF Series FILL SOLENOIDS 1 2 18 20 2 21 3 22 19 ASCO 17 14 ELTEK 15 16 KIP SKINNER 9 4 5 10 11 12 6 13 7 8 P3918 36 40566 040109
ITEM PART NO. 1 07441.0000 02308.0000 01327.0000 01502.0000 2 4 4 4 1 2 2 2 Bracket, Solenoid Mounting Screw, #8-32 X .375˝ (Bracket - Bracket) Screw, Pan Head #10-32 x .375˝ (Bracket - Solenoid) Lockwasher, Split #10 (Bracket - Solenoid) 2 00402.0001 2 1 Connector, Male .25˝ Flare x .125˝ MPT (2 Used On Early Models) 3 22397.0001 2 1 Fitting, .25˝ Barb x .125˝ MPT (Current Models) 4 01085.0000 01975.0000 21180.0000 2 2 2 1 1 1 Solenoid Valve, 120V - 1.
Part III C/CT/CWTF Series FAUCET AND TUBING 1 Early Models 4 5 11 10 9 8 6 14 12 1 13 7 4 2 3 P3919 38 40566 101507
FAUCET AND TUBING ITEM PART NO. QTY. TWIN QTY. SINGLE 1 20691.0001 20691.0000 1 1 1 1 Tube Assembly, Coil to Faucet (Early Models) Tube Assembly, Coil to Faucet (Late Models) 2 13059.0000 1 1 Faucet Jam Nut 3 01532.0000 1 1 Lockwasher, Internal Tooth .438” I.D. 4 12915.0000 1 1 Faucet, Hot Water (Includes items 5 thru 14) 5 13061.0000 1 1 Faucet Handle/Stem Assembly (Includes items 6 thru 11) 6 13053.0000 1 1 Faucet Handle Kit (Includes item 7) 7 02858.
Part III C/CT/CWTF Series WARMER ASSEMBLIES UPPER & SIDE HOUSING WARMERS A 3 1 4 5 6 120V & 120/240V MODELS ONLY ‘A” &”B” MODELS ONLY BASE WARMERS B 7 7 3 2 4 5 6 ‘A” &”B” MODELS ONLY 120V & 120/240V MODELS ONLY P3701.
ITEM PART NO. A 03652.0000 11440.0009 11440.0011 01303.0000 00916.0000 WARMER ASSEMBLIES QTY. TWIN QTY. SINGLE Part III DESCRIPTION 1 Warmer Assembly 120V, Top & Side Warmers (Includes items 1, & 3 - 6) 1 Warmer Assembly 220V, Top & Side Warmers (Includes items 1, 3, 5, & 6) 1 Warmer Assembly 200V, Top & Side Warmers (Includes items 1, 3, 5, & 6) 3 Screw, Pan Head - SST #4-40 x .5˝ 3 Fastener, J-Type #4-40 1 01227.0000 1 Warmer Element 120V Top & Side Warmers 01951.
Part III C/CT/CWTF Series ELECTRICAL AND OPERATING CONTROLS 1 Later Twins w/Two Cords 3 4 5 6 Later Twins w/One Cord 9 Early Twins w/One Cord 7 8 13 18 17 10 41 42 11 43 12 26 20 27 28 22 34 35 36 2 14 21 Brewers w/Switch Cover 40 23 19 16 20 38 28 39 37 15 13 25 31 29 Brewers w/Fresh Timer 30 Electronic Thermostat 20 28 24 32 P3920.
ELECTRICAL AND OPERATING CONTROLS QTY. TWIN QTY. SINGLE Part III ITEM PART NO. DESCRIPTION 1 28004.0000 40763.0001 - 2 2 Toggle Switch, (DPST) (Includes Hex Nut) (A Models) Toggle Switch, (DPST) (Includes Hex Nut) (4 Used on 0/6 Twin w/2 Cords) 2 23522.0001 - 1 Toggle Switch, (Dual Volt, SPDT) (Includes Hex Nut) 3 25102.0000 25102.0001 - 1 1 Bracket, Switch Guard (ON/OFF) Bracket, Switch Guard (I/0) 4 23696.0000 2 1 Hex Nut (2 Used on DV) 5 23697.
Part III C/CT/CWTF Series ELECTRICAL AND OPERATING CONTROLS 1 Later Twins w/Two Cords 3 4 5 6 Later Twins w/One Cord 9 Early Twins w/One Cord 7 8 13 18 17 10 41 42 11 43 12 26 20 27 28 22 34 35 36 2 14 21 Brewers w/Switch Cover 40 23 19 16 20 38 28 39 37 15 13 25 31 29 Brewers w/Fresh Timer 30 Electronic Thermostat 20 28 24 32 P3920.
Part III ELECTRICAL AND OPERATING CONTROLS ITEM PART NO. QTY. TWIN QTY. SINGLE DESCRIPTION 24 12984.0002 12984.0004 04243.0000 2 4 1 1 2 Ready Light, 120V Green Neon (Includes Hardware as Shown) Ready Light, 240V Green Neon (Includes Hardware as Shown) Terminal Housing, Plastic 25 12517.0003 25292.0000 34130.0000 03851.0000 2 2 2 4 1 1 1 2 LED, Fresh Timer (Includes Hardware as Shown) Lock Washer, M6 Nut, M6 Wire Nut 26 28177.0000 01317.
Part III C/CT/CWTF Series ELECTRICAL AND OPERATING CONTROLS 1 Later Twins w/Two Cords 3 4 5 6 Later Twins w/One Cord 9 Early Twins w/One Cord 7 8 13 18 17 10 41 42 11 43 12 26 20 27 28 22 34 35 36 2 14 21 Brewers w/Switch Cover 40 23 19 16 20 38 28 39 37 15 13 25 31 29 Brewers w/Fresh Timer 30 Electronic Thermostat 20 28 24 32 P3920.
ELECTRICAL AND OPERATING CONTROLS ITEM PART NO. QTY. TWIN QTY. SINGLE 38 34056.0000 - 1 Decal, Dual Volt 39 32400.0000 32400.0001 01320.0000 2 2 2 1 1 1 Digital Timer Kit, 120V Digital Timer Kit, 240V Screw, Round Head #8-32 x 1.0" (Late Models) 40 32530.0001 2 1 Spacer 41 37711.0000 37711.0001 02308.0000 2 2 4 1 1 2 Relay, 120V Relay, 240V Screw, Pan Head #8-32 x .375" 42 36256.0000 02308.0000 2 2 1 1 Bracket Screw, Pan Head #8-32 x .375" 43 38326.
Part III C/CT/CWTF Series ELECTRICAL AND OPERATING CONTROLS 1 Later Twins w/Two Cords 3 4 5 6 Later Twins w/One Cord 9 Early Twins w/One Cord 7 8 13 18 17 10 41 42 11 43 12 26 20 27 28 22 34 35 36 2 14 21 Brewers w/Switch Cover 40 23 19 16 20 38 28 39 37 15 13 25 31 29 Brewers w/Fresh Timer 30 Electronic Thermostat 20 28 24 32 P3920.
Part III ELECTRICAL AND OPERATING CONTROLS ITEM PART NO. QTY. TWIN QTY. SINGLE DESCRIPTION 59 27946.0000 - 1 Wiring Harness, Main (2 Warmers) 240V 60 28051.0000 - 1 Wiring Harness, Main APS/TC 240V & CE 61 33985.0000 - 1 Wiring Harness, Main (3 Warmers) 120V & Single CW-15 62 34005.0000 - 1 Wiring Harness, Main APS/TC (Pour In Only) 120V 63 34023.0000 34023.0002 - 1 1 Wiring Harness, Main (Single CW-15) 120/240V Wiring Harness, Main (4 Warmers) 120/240V 64 34023.
Part III C/CT/CWTF Series 1 Later Twins w/Two Cords 3 4 5 6 Later Twins w/One Cord 9 Early Twins w/One Cord 7 8 13 18 17 10 41 42 11 43 12 26 20 27 28 22 34 35 36 2 14 21 Brewers w/Switch Cover 40 23 19 16 20 38 28 39 37 15 13 25 31 29 Brewers w/Fresh Timer 30 Electronic Thermostat 20 28 24 32 P3920.
Part III ITEM PART NO. QTY. TWIN QTY. SINGLE DESCRIPTION 87 41390.0019 - 1 WIRING HARN, Main CWTF–DV 1 lwr 88 41390.0020 - 1 WIRING HARN, Main CWTF-35 TS/APS 89 41390.0021 - 1 WIRING HARN, Main CWTF-20 TS/APS 90 41390.0022 - 1 WIRING HARN, Main CWTF – APS 230v CE 91 41390.0023 - 1 WIRING HARN, Main CW-20 APS 92 41390.0024 - 1 WIRING HARN, Main CWTF -DV TC/APS 93 41390.0028 - 1 WIRING HARN, Main CWTF35A 230V 3LOWER/1UPPER 94 34023.
Part III C/CT/CWTF Series FUNNELS A B 2 5 1 3 14 15 4 14 15 6 16 Pouch Pack Funnel Plastic ‘C’ Funnel C 9 D 11 14 10 15 14 8 13 13 12 16 SST ‘C’ Funnel SST Gourmet ‘C’ Funnel 15 P3703 52 40566 101507
QTY. TWIN FUNNELS QTY. SINGLE Part III ITEM PART NO. DESCRIPTION A 1 1 2 2 20583.0003 29351.0001 20583.0006 33119.0000* 33127.0000* 32964.0000 32966.0000 2 2 1 1 1 1 1 1 1 Funnel Assy, 7.125"Black Plastic (Includes items 2, 14, & 15) Funnel Assy, 7.625"Black Plastic (Includes items 2, 14, & 15) Funnel Assy, 7.125" Orange Plastic (Includes items 2, 14, & 15) Funnel Body, 7.125" Black Plastic (Order item A) Funnel Body, 7.125" Orange Plastic (Order item A) Splashgard, Black Plastic, 7.
Part III NUMERICAL INDEX PART NO. PAGE NO. 00310.0000............... 31,33,35 00310.0002......................... 35 00400.0001......................... 21 00402.0001.................... 25,37 00419.0000......................... 25 00425.1000......................... 25 00436.0001......................... 27 00445.0001......................... 35 00459.0000............... 27,29,33 00459.0001......................... 31 00462.0001........................... 9 00463.0000.................... 27,29 00463.
Part III NUMERICAL INDEX 12984.0004......................... 45 12985.0000......................... 47 12985.0003......................... 47 13042.0001......................... 41 13053.0000......................... 39 13054.0000......................... 39 13055.0000......................... 39 13056.0000......................... 39 13057.0000......................... 39 13058.0000......................... 39 13059.0000......................... 39 13060.0000......................... 39 13061.0000........
Part III NUMERICAL INDEX PART NO. PAGE NO. 26285.0000......................... 11 26285.0001......................... 11 26285.0002......................... 11 26285.0006......................... 11 26285.0007......................... 11 26285.0008......................... 11 26287.0000......................... 11 26301.0000......................... 29 26318.0000......................... 29 26413.0000......................... 17 26413.0001......................... 17 26443.0000.........................
Ref: NAVSEAINST 4160.3A NAVSEA S0005-AA-GYD-030/TMMP NAVSEA/SPAWAR TECHNICAL MANUAL DEFICIENCY/EVALUATION REPORT (TMDER) INSTRUCTIONS: Continue on 8 ½” x 11” page if additional space is needed. 1. Use this report to indicate deficiencies, problems and recommendations relating to publications. 2. For CLASSIFIED TMDERs see OPNAVINST 5510H for mailing requirements. 3. For TMDERs that affect more than one publication, submit a separate TMDER for each. 4. Submit TMDERs at web site https://nsdsa.nmci.navy.
FOLD HERE AND TAPE SECURELY PLEASE DO NOT STAPLE INCLUDE COMPLETE ADDRESS USE PROPER POSTAGE FOR OFFICIAL USE ONLY COMMANDER CODE 310 TMDERs NAVSURFWARCENDIV NSDSA 4363 MISSILE WAY BLDG 1389 PORT HUENEME CA 93043-4307 FOLD HERE AND TAPE SECURELY PLEASE DO NOT STAPLE
Ref: NAVSEAINST 4160.3A NAVSEA S0005-AA-GYD-030/TMMP NAVSEA/SPAWAR TECHNICAL MANUAL DEFICIENCY/EVALUATION REPORT (TMDER) INSTRUCTIONS: Continue on 8 ½” x 11” page if additional space is needed. 1. Use this report to indicate deficiencies, problems and recommendations relating to publications. 2. For CLASSIFIED TMDERs see OPNAVINST 5510H for mailing requirements. 3. For TMDERs that affect more than one publication, submit a separate TMDER for each. 4. Submit TMDERs at web site https://nsdsa.nmci.navy.
FOLD HERE AND TAPE SECURELY PLEASE DO NOT STAPLE INCLUDE COMPLETE ADDRESS USE PROPER POSTAGE FOR OFFICIAL USE ONLY COMMANDER CODE 310 TMDERs NAVSURFWARCENDIV NSDSA 4363 MISSILE WAY BLDG 1389 PORT HUENEME CA 93043-4307 FOLD HERE AND TAPE SECURELY PLEASE DO NOT STAPLE
S6163-AK-FSE-010