Coffee Grinder User Manual

Page 36
PROGRAMMING THE BREWER (cont.)
BREW COUNTERS
This function allows the operator to track the num-
ber of brew cycles completed. There is one resettable
counter, and one life counter that is not resettable.
EXIT TO
NEXT FUNCTION
SCREEN
XXXX
NEXT RESET
XXXX
NEXT
BREW COUNTERS?
NO YES
Procedures to view/reset the brew counters:
1. Press and hold the upper right hidden switch until
the display reads UNITS. Release the switch, then
press and release switch until the display reads
BREW COUNTERS.
2. Pressing NO in this screen will advance to the next
function. Press YES to view the first brew counter.
This number represents the brew cycles initiated
since that counter was last reset.
3. To reset the resettable counter to zero press
and release RESET when viewing that particular
counter's screen.
P2448
Procedure to set funnel detect:
1. Press and hold the upper right hidden switch until
the display reads UNITS. Release the switch, then
press and release switch until the display reads
FUNNEL DETECT.
2. NO or YES should be flashing to indicate the cur-
rent setting.
3. Select YES to prevent brewing if a Smart Funnel is
not correctly situated in the rails. If this function is
activated and a brew cycle is attempted with the
funnel not properly situated, the display will read,
FUNNEL NOT IN PLACE, until one is in place.
4. Select NO to allow brewing without a Smart Fun-
nel in place. This is selected when brewing with a
funnel other than a Smart Funnel (a regular brew
funnel).
5. When finished, press and release DONE. This will
retain the changes, exit this function screen and
advance to the next. Another alternative is to press
the ON/OFF switch located on the front switch
panel to exit the FUNNEL DETECT and return to
the MAIN SCREEN.
7. Measure the amount of water in the container, and
using (-) or (+), adjust the amount on the display
to match the amount in the container. Then press
DONE.
8. The display should now read NEW BYPASS FLOW,
along with the correct flow rate of the bypass in
ounces per minute. After about 5 seconds, the dis-
play will return to the CALIBRATE FLOW screen.
9. To exit the CALIBRATE FLOW function, press and
release NO to advance to the next function screen,
or press the ON/OFF switch located on the front
switch panel to exit the CALIBRATE FLOW function
and return to the MAIN SCREEN.
CALIBRATE FLOW (cont.)
4. To advance to the other counter, press and release
NEXT. This will advance to total brews (non-reset-
table).
5. When finished, press NEXT until the display reads
BREW COUNTERS. Press and release NO to ad-
vance to the next function screen, or press the
ON/OFF switch located on the front switch panel
to exit the BREW COUNTERS function and return
to the MAIN SCREEN.
FUNNEL DETECT (optional)
This function allows the operator to prevent the
start of a brew cycle if a Smart Funnel is not positioned
correctly in the funnel rails.
P2721
FUNNEL DETECT ?
NO DONE YES
35879.1 071405