User Instruction Manual T I T A N Commercial Catering Range Please read and keep these instructions These instructions cover the Burco Titan Dual Fuel 6 Burner Commercial Catering Range RG90DF/NG, RG90DF/LP, SKU’s 444440350, 444440414 RG90DF/NG, RG90DF/LP SKU’s 444440350, 444440414 Glen Dimplex Professional Appliances Stoney Lane, Prescot, Merseyside, L35 2XW Tel: 0844 815 3755 www.burco.co.
INTRODUCTION This appliance must be installed by a competent person in compliance with the installation and servicing instructions and national regulations in force at the time. Particular attention must be paid to the following: Gas Safety (Installation & Use) Regulations. Health and Safety at Work etc Act. Adjustment must not be made by the user to parts which are protected by the manufacturer.
TO INSTALLATION, ESPECIALLY IN DAMP CONDITIONS, THE INSULATION RESISTANCE OF THE ELEMENTS MAY FALL TO AN UNACCEPTABLE LEVEL. (I.E. BELOW 2 MEGOHM). SHOULD THIS OCCUR, IT IS RECOMMENDED THAT THE ELEMENTS BE SWITCHED ON FOR AN HOUR, THEN ALLOWED TO COOL. THIS PROCESS BEING REPEATED AS NECESSARY TO RESTORE THE REQUIRED INSULATION RESISTANCE.
INSTALLATION AND SERVICE GUIDE IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL. PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommend that a Maintenance Contract be arranged. Visits may then be made at agreed intervals to carry out adjustments and repairs. WEEE directive registration no.
the national requirements in force and shall be periodically examined and replaced as necessary. The installation must be tested for gas tightness. Details of this procedure can be found in IGE/UP/1. 1.4 ELECTRICAL SUPPLY This appliance is suitable for AC supplies only. The standard unit terminal arrangement is for use on a two phase supply (with neutral), terminal block 1. By adding the links, positioned between L1, L2 and L3 on terminal block 2, the range can be converted for single phase.
Connect a manometer and check that supply pressure is correct when the oven burner is ignited and then turned to the highest temperature setting. 1.8 BURNER ADJUSTMENT - NATURAL AND PROPANE GAS Hotplate and oven burners are fitted with fixed bypass screws and set aeration apertures, NO ADJUSTMENT is possible. SECTION 2 - ASSEMBLY AND COMMISSIONING 2.1 ASSEMBLY Assembly of Ranges Note: The following paragraphs should be read as applicable to the unit being assembled. 1.
2.4.3 Lighting sequence Important: Prior to operation, ensure ALL packing material has been removed from appliance. Hotplate 1. Ensure mains gas is turned on. 2. To light hotplate burners, press knob and turn to full flame position. Ignite burners using taper or match. Hold in knob for 5 - 10 seconds and then release. Check burner remains lit and turn knob to required position. 3. To turn the hotplate off, turn knob to OFF position. Oven 1. Switch on electrical supply at mains.
3.1.5 Cleaning Burners should be cleaned periodically to maintain maximum performance. Open top burners should be cleaned as detailed in User Instructions. 3.2 INJECTORS 3.2.1 Hotplate 1. Remove burner caps and skirts. 2. Undo and carefully remove injector. 3. Replace in reverse order. 3.3 THERMOCOUPLES AND FLAME FAILURE DEVICE (FFD) 3.3.1 Hotplate flame failure device magnet unit 1. Undo thermocouple at FFD section of gas tap. 2.
3.8 RELAYS 1. Remove cover plate from rear terminal box. 2. Undo electrical connections from relay and remove fixings. 3. Replace in reverse order. Electrical connections to be restored as detailed in wiring diagram. 3.9 CONTROL FUSE The control fuse is located within rear terminal box. 3.10 THERMAL CUTOUT A thermal cutout is fitted to oven chamber back panel. Access is through outer back panel cover plate. To reset, press button in centre of cutout. To remove, undo bracket fixings.
USER’S GUIDE SECTION 1 - ABOUT YOUR APPLIANCE All models are fitted with flame failure devices to shut off gas supply to burners if flames are extinguished. The oven is thermostatically controlled. All taps are the safety type with fixed HIGH and LOW settings. Hotplate controls Control knob markings are as indicated below. Off High Low Oven thermostat The oven is thermostatically controlled. The control knob markings are in degrees celsius.
IMPORTANT INFORMATION PLEASE READ THE FOLLOWING VERY CAREFULLY....AVOID MIS-USE! (MIS-USE OF THIS PRODUCT CAN BE HARMFUL). Guidance Rules for the SAFE USE of a gastronome pan on the hotplate, Size 2/1 or 1/1 gastronome pans. • • • • • • • • • • • • Whenever two or more hotplate burners are operated below a gastronome pan, the heat input of each burner should be reduced. If only two burners are to be used, we recommend you use one front burner and one rear burner as a pair.
SECTION 4 - CLEANING AND MAINTENANCE All surfaces are easier to clean if spillages are removed before they become burnt on and if units are cleaned daily. Stainless steel surfaces These surfaces should be cleaned with hot water and detergent then dried and polished with a soft cloth. Cleaning agents containing bleach, abrasives or caustic chemicals will damage or mark the stainless steel surfaces and must not be used.
Oven Clean while oven is warm but not hot. The enamelled base plate lifts out. The shelf guides can be removed by removing the four fixings. The oven base is removed by lifting at the front, and pulling towards you. GUARANTEE This appliance is guaranteed against defective materials or faulty workmanship, for a period of 12 months on labour and 36 months on parts.
TITAN DUAL FUEL WIRING DIAGRAM Wiring colour code: Bk - Black, Bn - Brown, Bu - Blue, Gn/Y - Green/Yellow, Or - Orange, W - White, Y - Yellow.
SPARES LIST Part Number 082982600 082982500 532991800 532991900 502991600 503058100 082983500 012980500 082983800 082983802 080125000 082984000 081367387 083056100 082986700 502992900 082980700 082558001 083064900 083064901 082983600 082983601 082233900 081581800 082971300 083055600 082930601 082930602 083055700 082758302 Description Burner cap assembly Burner skirt Oven door outer left hand side Oven door outer right hand side Door oven inner panel Facia panel Handle door Hotplate assembly Control knob (h
Customer helpline For spares and after-sales service please contact Burco on: T: 0844 815 3755 F: 0844 815 3748 E: info@gdha.com Glen Dimplex Professional Appliances (A Division of Glen Dimplex Home Appliances) Stoney Lane, Prescot, Merseyside L35 2XW www.burco.co.uk 082758302 © 07.