Page 10
Trouble Look For Remedy
(Symptom) (Probable Cause) (Corrective Action)
TROUBLESHOOTING
Poor fog quality. 1.) Low voltage. 1.) Change to another power source.
2.) Too light a gauge 2.) Use only 3 wire, 10 ,12 or 14 gauge
extension cord. extension cords suitable for outdoor
usage. Never defeat grounding
feature. Failure to comply may result
in electrical shock and / or re.
3.) Fogger is not at 3.) Wait 10-15 seconds before pumping.
operating temperature.
4.) If fog is wet and dripping the 4.) Decrease your pumping rate. See
pumping rate is too high or it Figure 6.
has not reached operating
temperature.
No fog 1.) Nozzle and/or end of 1.1.) Remove and clean nozzle orice.
Barrel heats up. coil obstructed or See Figure 1 & 2.
clogged.
1.2.) Remove carbon build-up from inside
the coil if necessary. See Figure 3.
2.) Pump plugged. 2.1) Insert a small diameter wire or tooth
toothpick into hole at bottom of
Piston Assembly to clear
obstruction. See Figure 4.
2.2) Replace pump assembly, (Kit #3).
3.) Piston is worn. 3.) Replace piston assembly, (Kit #3).
4.) Improper fogging 4.) Use only Black Flag ® Formula 2,
material. Cutter ® or Repel ® Fogging Insecticide.
No fog-Barrel does 1.) No voltage. 1.) Change to another power source.
not heat up.
2.) Bad extension cord. 2.) Change to another extension cord.
3.) Heater assembly defective. 3.) Return you fogger for factory service.
Do not attempt to repair the heater
assembly. Not customer serviceable.
Dripping 1.) Nozzle loose. 1.) Tighten nozzle securely. See Figure 5.
2.) Excessive insecticide 2.) Pump with a lower rate. See Figure 6.
output.