Datasheet

46 Burgess switches
www.burgess-switch.com
info@burgess-switch.com
V3S
Operating Characteristics
Actuating Release Free Operating Movement
Actuator Reference Force Force Position Position Differential
Maximum Minimum Maximum Maximum
(N) (ozf) (N) (ozf) (mm) (in) (mm) (in) (mm) (in)
Plunger
V3SUL 3,90 14,0 1,10 4,00 15,9 0,63 14,5 ± 0.5 0,57 ± 0.02 0,4 0,016
Plain lever
V3SY1UL 1,65 6,0 0,42 1,50 13,4 0,71 14,9 ± 1,0 0,59 ± 0.4 1,0 0,040
Roller lever - short
V3SYRUL 3,90 14,0 1,10 4,00 22,1 0,87 20,45 ± 0.64 0,8 ± 0.025 0,40 0,016
Roller lever - long
V3SYR1UL 1,65 7,5 0,42 1,50 18,1 0,71 14,9 ± 01.0 0,55 ± 0.039 1,00 0,040
Over travel: Plunger can be depressed flush with housing. The housing should not be used as an end stop.
Ø4.78 X 4.78
[Ø0.19 X 0.19]
24.2
[0.95]
[0.46]
Ø4.78 X 4.78
[Ø0.19 X 0.19]
11.7
26.2
[1.03]
Ø4.78 X 4.78
[Ø0.19 X 0.19]
24.2
[0.95]
[0.46]
Ø4.78 X 4.78
[Ø0.19 X 0.19]
11.7
26.2
[1.03]
Ø4.78 X 4.78
[Ø0.19 X 0.19]
24.2
[0.95]
[0.46]
Ø4.78 X 4.78
[Ø0.19 X 0.19]
11.7
26.2
[1.03]
Basic type
V3S
Circuit No symbol, change-over
C2 Normally closed
C4 Normally open
Actuators
No symbol, without lever or actuator
Y1 Plain lever 26.2 mm
YR Roller lever 11.7 mm
YR1 Roller lever 24.2 mm
Contact Material No symbol, Ag
GP Gold plate on silver (GP)
Terminals No symbol, fitted with standard 500 mm cables
Approvals
No symbol, without approval
UL UL and CSA approval
Special Features
/ Burgess specialise in customer specific solutions.
Additional product variants are available or can be provided.
If your requirements cannot be satisfied from the options listed,
please contact www.saia-burgess.com or your local SB outlet.
Ordering Reference
Example: V3S C2 Y1 GP UL
Miniature sealed