Instructions

5
Special instructions for valves circuit function B (NO) with
deaeration connection G1/8 on the coil (CF05/MX62):
The deenergized valve is open. The
medium also ows o via the deaeration
connection on the coil.
Valves of this design are therefore
suitable for relieving compressors only.
4.2 Application conditions
Ambient temperature: max. +55°C
Operating duration: Unless otherwise indicated on the type
label, the solenoid system is suitable for
continuous operation
Important information for functional reliability during con-
tinuous operation.
If standstill for a long period at least 1-2 activations per day
are recommended.
Service life: High switching frequency and high pres-
sures reduce the service life
Permitted medium temperature depending on coil and seal material:
Coil body
PA/EP
1)
Seal material Medium temperature
Polyamide PA FKM 0...+90°C
Epoxy EP (NA38) FKM 0...+120°C
Polyamide PA EPDM -30...+90°C
Epoxy EP (NA38) EPDM -30...+100°C
Polyamide PA NBR -10...+80°C
1) Marking PA and EP under electric connection
Permitted media depending on seal material:
Seal material Permitted media
2)
FKM Per-solutions, hot oils without additives, diesel
and heating oil without additives, detergent
solution
EPDM Oil and grease-free liquids, cold and warm
water
NBR Cold and warm water
2)
Gaseous media at low dierential pressures (e.g. compressed air and vacuum)
can also be actuated in consideration (or due to restriction) of a lower
tightness. We recommend prior clarication with our sales oce regarding
the possible application
english