Instructions

9
Note the voltage and current type as specied on the type
label.
Authorized cable plug e.g. Type 2508 or
other suitable cable plug in accordance
with DIN EN 175301-803 Form A
Seal
max. 1 Nm
Pulse version (optional, Code CF 16):
1
2
Valve opens when current pulse min. 50 ms:
– on Pin 1, + on Pin 2
Valve closes when current pulse min. 50 ms:
+ on Pin 1, – on Pin 2
6 MAINTENANCE, TROUBLESHOOTING
6.1 Safety instructions
WARNING!
Risk of injury from improper maintenance.
Maintenance may be carried out by authorized technicians only
and with the appropriate tools.
Risk of injury from unintentional activation of the system and an
uncontrolled restart.
Secure system from unintentional activation.
Following maintenance, ensure a controlled restart.
6.2 Installation of the coil
WARNING!
Risk of injury due to electrical shock.
Before reaching into the system, switch o the power supply and
secure to prevent reactivation.
During installation ensure that the coil is situated rmly on the
body cover so that the protective conductor connection of the
coil is connected to the valve body.
Check protective conductor contact after installing the coil.
english