DATA SHEET Type 6014 Plunger valve 3/2 way direct-acting • Direct-acting, compact valve with diameter of up to DN 2.5 • Vibration-proof, bolted coil system • Banjo threaded connection for direct mounting on pneumatic valves • Service-friendly manual override • Energy-saving impulse versions Product variants described in the data sheet may differ from the product presentation and description. Can be combined with Type description Type 2513 Cable plug acc.
Type 6014 Table of contents 1. General Technical Data 4 2. Circuit functions 4 3. Approvals 5 4. Materials 5 4.1. 4.2. 5. Dimensions 5.1. 5.2. 5.3. 5.4. 5.5. 5.6. 6. 16 Installation notes...................................................................................................................................................................16 Control for impulse version with polarity reversal control...................................................................................
Type 6014 9.4. Ordering chart accessories...................................................................................................................................................24 Cable plug Type 2518, Form A according to DIN EN 175301 - 803......................................................................................24 Cable plug Type 2513, form A acc. to DIN EN 175301 - 803...............................................................................................
Type 6014 1. General Technical Data Product properties Dimensions Detailed information can be found in chapter “5. Dimensions” on page 8. Material Seal Body Coil Nominal diameter Thermal insulation class of solenoid Performance data Duty cycle / single valve assembly Circuit function Electrical data Operating voltage Voltage tolerance Medium data Medium temperature FKM (EPDM on request) Brass or stainless steel, polyamide (sub-base) Polyamide (Epoxy on request) DN1.5…DN2.
Type 6014 3. Approvals ATEX and IECEx approval for coils with fixed cable outlet ATEX: EPS 18 ATEX 1232 X II 2G Ex mb IIC T4 Gb II 2D Ex mb IIIC T130 ºC Db Explosion-proof approvals ATEX: PTB 01 ATEX 2101 0102 II 2G Ex i IIC T6 Gb II 2D Ex i IIIC T85 ºC Db 4. IECEx: IECEx EPS 18.0110X Ex mb IIC T4 Gb Ex mb IIIC T130 ºC Db IECEx: PTB IECEX12,0040 Ex ia IIC T6 Gb Ex ia IIC T80 °C Db Materials 4.1.
Type 6014 Banjo version 17 No. Element 1 Locknut 1 2 3 4 5 6 7 8 9 10 11 12 2 3 4 5 6 7 8 13 14 16 15 13 12 9 10 11 12 13 14 15 16 17 Material Steel, surface finish thick-film passivated (brass version) Stainless steel 1.4305 PTFE coated (stainless steel version) Coil PA (Polyamide) Epoxy (High temperature version) Stopper Stainless steel 1.4105 Shading ring Cu (brass version) Ag (stainless steel version) Armature guide tube Stainless steel 1.4303 Magnetic core Stainless steel 1.
Type 6014 ATEX/IECEx m junction box version 1 2 3 4 5 6 7 8 14 9 10 13 11 12 No. Element 1 Locknut 2 3 4 Stopper Coil Shading ring 5 6 7 8 9 10 11 Plunger seal Spring Magnetic core Armature guide tube O-rings Plunger seal Valve body 12 13 Spring Sub-base 14 Junction box Visit product website Material Steel, surface finish thick-film passivated (brass version) Stainless steel 1.4305 PTFE coated (stainless steel version) Stainless steel 1.
Type 6014 5. Dimensions 5.1. Standard version Note: Dimensions in mm Threaded version G1/8 + G1/4 Flange version 5.4 Ø 6.3 Ø 3.2 14.6 24 9 15 ** 27 18 G1/8 52.8 12 10 C C 7 G * B D *** M4 E A 24 32 35 5.6 (4x) M4 8 SW14 F Port connection A [inch] Threaded without manual override G ⅛ G¼ Threaded with manual override G⅛ G¼ Sub-base – Coil size B [mm] C [mm] D [mm] G [mm] 32 46 32 46 32 20.8 26.8 20.8 26.8 14.3 32.6 49 32.6 49 32.
Type 6014 5.2. Banjo version Note: Dimensions in mm BJ01 - BJ07 E 27 18 9 15 F G1/8 A P 82.8 14.6 52.8 12 10 SW17 32 G 8 6.5 76 14.2 96.
Type 6014 5.3. ATEX/IECEx m cable version Note: Dimensions in mm Threaded version G1/8 + G1/4 Flange version Ø 6.3 Ø 3.2 G1/8 5.4 C 24 52.8 Cable length acc. to order specification (4x) M4 8 7 G B D E M4 5.6 C A 24 32 35 SW14 F Port connection Threaded version Sub-base version Coil size 5 6 A [inch] G⅛ G¼ – B [mm] 32 46 32 E [mm] 32 40 Visit product website C [mm] 20.8 26.8 14.3 D [mm] 32.6 49 32.
Type 6014 5.4. ATEX/IECEx m junction box version Note: Dimensions in mm Threaded version G1/8 + G1/4 Cable gland included in the scope of delivery 68 M20x1.5 5.4 C 52.8 105 G1/8 (4x) M4 G 8 B D E A 24 32 35 SW14 F 43.2 75.3 Port connection Threaded version Sub-base version Coil size 5 6 A [inch] G⅛ G¼ – B [mm] 32 46 32 E [mm] 32 40 Visit product website C [mm] 20.8 26.8 14.3 D [mm] 32.6 49 32.
Type 6014 5.5. ATEX/IECEx ia Note: • Dimensions in mm • Detailed information about electrical data see “6.3. Electrical data” on page 15. Threaded version G1/8 G1/8 14.6 52.8 9 15.4 24 32 Ø 6.3 Ø 3.2 12 10 Flange version 27 18 5.4 20.8 7 6.5 M4 SW14 40 G1/8 24 32 35 23.3 (4x) M4 8 8 32 32.
Type 6014 5.6. Manifold mounting Single manifold Note: • Dimensions in mm • Detailed information about installing manifolds see “Manifolds for block mounting” on page 16. 8 17 13 2.5 Ø 10.5 8 G1/8 24 32 M5 Ø 7.2 4.
Type 6014 Multiple manifold Note: Dimensions in mm A C 16 33 33 B Note: Brass or stainless steel manifolds on request Accessory parts Number of valve positions Total length B [mm] 65 Hole spacing C [mm] – Article no.
Type 6014 6.2. Utilisation in another circuit function The valves are equipped with different springs for specific circuit functions. When used with other circuit functions, the permissible operating pressure changes according to the following table. Standard version DN Max. operating pressure [bar] for valve application in circuit function A B C D T Circuit function C D T C D T C D T 1.5 2.0 2.5 16 2 10 10 1 6 6 0.7 3.5 22 2.5 16 14 1.5 10 9 1 6 16 2 10 10 1 6 6 0.7 3.5 2 16 6 1 10 4 0.7 6 2.
Type 6014 7. Product installation 7.1.
Type 6014 Description Ex approvals Certification PTB 13 ATEX 1015 X, IECEx PTB 13.0034X Ex cable gland, Polyamide, 7…13 mm Dimensions Identification II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 TL L D SW E 36…45 mm 10 mm 20 mm 24 mm 28 mm 8.2. Special tool to turn the junction box Note: This special tool is not supplied with the valve (see “9.4. Ordering chart accessories” on page 24). Description Set SC02-AC10 Components of the set • Special wrench • Service manual 9. Ordering information 9.1.
Type 6014 9.3. Ordering chart Standard version Note: Delivered without cable plug (see accessories) Circuit function Orifice Port KV value connection water1.) [mm] [m3/h] Threaded version with FKM seal, (class B) Brass body 1.5 G⅛ 0.07 C, solenoid valve 3/2 way 2.0 G⅛ 0.11 Direct-acting G ¼ 0.11 Normally closed 2.5 G⅛ 0.16 2(A) 1(P) Coil power Article no.
Type 6014 Circuit function Stainless steel body C, solenoid valve 3/2 way Direct-acting Normally closed Orifice [mm] Port KV value connection water1.) [m3/h] Pressure range2.) [bar] Coil power Article no. per voltage / frequency 024/DC 024/50 230/50 [W] 1.5 G⅛ 0.07 0…16 8 126216 126217 126219 2.0 G⅛ 0.11 0…10 8 2.0 G¼ 0.11 0…10 8 126220 126224 126221 126225 126223 126227 1.5 G⅛ 0.07 0…7 8 126228 126229 126231 KV value water1.) Pressure range2.
Type 6014 Circuit function Polyamide body C, solenoid valve 3/2 way Direct-acting Normally closed Orifice KV value water1.) 1.5 [m3/h] Pressure range2.) [bar] Coil power Article no. per voltage / frequency 024/DC 024/50 230/50 [W] 0.07 0…10 5 126390 126391 126393 0.07 0…10 5 126396 126397 126399 2(A) 1(P) 3(R) With manual override C, solenoid valve 1.5 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) 1.) Measured at + 20 °C, 1 bar2.) pressure difference 2.
Type 6014 Circuit function Pressure inlet P Service port A (banjo bolt) Orifice QNn value air Material banjo bolt PresPower Article no. sure consumpper voltage/frequency [V/Hz] range tion [mm] [l/min] [bar] [W] 024/DC 024/50 230/50 With polyamide body, FKM seal and manual override, IXEF® banjo coupler, anodised aluminium banjo bolt x x C, solenoid G⅛ G¼ 1.5 75 PA 0…10 5 784710 valve G⅛ G¼ 2.0 120 PA 0…10 8 784706 784707 784709 3/2 way G ⅛ G ¼ 2.
Type 6014 Circuit function Orifice Port connection [mm] T, solenoid valve 3/2 way Direct-acting Flow direction optional 1.5 G⅛ KV value Pressure water range [bar] [m3/h] Body material 0.07 MS 0…7 [W] Voltage/ frequency [V/Hz] Article no. without manual override 9 024/UC 364573 x VA 9 230/UC 024/UC MS 9 VA 9 230/UC G¼ 0.07 0…7 2(A) 1(P) Coil power 024/UC 230/UC 024/UC 230/UC 3(R) 352009 351989 x x 351994 x Article no.
Type 6014 Circuit function Orifice Port connection [mm] T, solenoid valve 3/2 way Direct-acting Flow direction optional 1.5 G⅛ G¼ KV value Pressure water range [bar] [m3/h] Body material 0.07 MS 0.07 2(A) 1(P) 0…7 0…7 Coil power [W] Voltage/ frequency [V/Hz] Article no. without manual override 9 024/UC 364606 x x x x x VA 9 MS 9 VA 9 230/UC 024/UC 230/UC 024/UC 230/UC 024/UC 230/UC 3(R) 364610 364611 Article no.
Type 6014 9.4. Ordering chart accessories Cable plug Type 2518, Form A according to DIN EN 175301 - 803 Note: Further versions see data sheet Type 2518 . Cable plug Dimensions 29.2 M3 ca. 51 Ø 19 1.5 3.5 35.7 Version Without circuitry (AC/DC) Voltage 0…250 V AC/DC Article no. With LED (AC/DC) 12…24 V AC/DC 314812 With LED and varistor (AC/DC) 12…24 V AC/DC 314820 With rectifier, LED and varistor 12…24 V AC/DC 314816 314802 29.2 Cable plug Type 2513, form A acc.
Bürkert – Close to You For up-to-date addresses please visit us at www.burkert.com Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom Russia China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan Canada USA United Arab Brazil Uruguay Emirates South Africa Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co.