Owner's manual
10 - 1066
TECHNICAL DATA
english
Pneumatic data
Port connections Compressed air/Exhaust air G 1/4
Service ports tube hose connection
6/4 mm or 1/4 inch, plug-in
Pressure range 2.5 to 7 bar
Air flow, control valve 110 l/min Type 6510, 40 l/min Type 6106
Flow: Q
Nn
- value air (l/min)
Measurement at +20 °C, 6 bar pressure at the valve inlet and 1 bar
pressure difference
Response times Type 6510 / Type 6106
Opening 15 / 23 ms Closing 10 / 21 ms
Measurement at valve outlet at 6 bar and +20 °C
Opening: pressure rise 0 to 90 %
Closing: pressure fall 100 to 10 %
Control range min. stroke 2mm max. stroke 73 mm
Electrical data
Protection class IP 67
Operating voltage
without communication 24 V DC ±10 %
24/110/230 V UC ±10 %
with communication in accordance with the ASI and DeviceNet specification
Max. electrical power loss 5 W for 3 x Type 6510 or 1 x Type 6106
Connections
Control heads
without communication: Multipol (8-pole round plug DIN 45326) for 24 V DC
(8-pole screw terminals) for 24 V DC
2 x 6-pole screw terminals for 24/110/230 V UC
Control heads
with communication:
ASI: Cut-clamp connector and cable fitting
M12 plug and cable fitting
M12 flange plug, 4-pole
DeviceNet: 5-pole M12 plug connection
Solenoid valves
Nominal power 1 W Type 6510 / 3 W Type 6106
Operating mode continuous (ED 100 %)
Proximity switches
Operating voltage 8 to 30 V DC
Output signal max. 100 mA, short-circuit proof
Micro-switch potential-free, max. 1 A switched current