Manual

25
Installation and wiring
Type 8011
Correct
Incorrect
Fig. 7: Filling the pipe
7.2.2. Installing a device with welding
ends
note
The SE11 electronic module and the seal may be damaged
when welding the connections to the pipe.
Before welding to the pipe, unscrew the 4 locking screws on
the SE11 electronic module.
Remove the electronic module.
Remove the seal.
Follow the installation recommendations in chap. 7.2.2.
Weld the connections.
After welding the connections to the pipe, correctly replace the
seal.
Properly replace the electronic module.
Tighten the 4 screws in an alternating pattern, applying a torque
of 1.5 Nm.
7.2.3. Installing a device with Clamp
connections
Follow the installation recommendations in chap. 7.2.1.
Check that the seals are in good condition.
Place the seals, that have been chosen depending on the
process temperature and fluid, into the grooves of the
Clamp connections.
Fit the Clamp connections to the pipe using a clamping collar.
7.2.4. Installing a device with flange
connections
Follow the installation recommendations in chap. 7.2.1.
Check that the seals are in good condition.
Insert a seal, that has been chosen depending on the
process temperature and fluid, into the grooves of the
connections.
Make sure the seal remains in its groove when tightening
the flange.
Tighten the flange to mount the device to the pipe.
English