Manual
28
Installation and wiring
Type 8011
7.4.1. Assembling the M12 female connector
1 2
→ Completely unscrew the
nut [1]
→ Remove the rear section of
the connector [2].
→ Wire the device (see chap.
7.4.2)
Fig. 8: M12 multi-pin connector (not supplied, ordering code
917116)
7.4.2. Wiring a version with M12 fixed
connector
note
• For the electrical connection of a version with an M12 fixed con-
nector, use a straight connector.
4
5
3
1
2
0 VDC
V+
(*)
Not connected
NPN pulse output
Version with 1 pulse output
4
5
3
1
2
0 VDC
V+
(*)
NPN pulse output
PNP pulse output
Version with 2 pulse outputs
Fig. 9: Pin assignment of the M12 male fixed connector
(*) Functional earth;
Pin of the M12 female cable available as
accessory equipment (order code 438680)
Color of the
wire
1 brown
2 white
3 blue
4 black
5
grey
+-
(*)
1 2
34
5
Power supply, 4,5-24 V DC or
6-36 V DC
Load
blue
grey
white
brown
Fig. 10: NPN wiring of the pulse output of a version with M12
fixed connector
(*) Functional earth; If a direct earth connection is not possible, fit a 100 nF /
50 V capacitor between the negative power supply terminal and the earth.
English