Technical data
Type 8012
6. TECHNICAL DATA
6.1. Conditions of use
Ambient temperature -15 to +60 °C
Air humidity < 80%, non condensated
Protection rating IP67 (version with M12 fixed
connector), female connector wired,
plugged in and tightened
IP65 (version with cable gland)
6.2. Conformity to standards and
directives
The device conforms to the EC directives through the following
standards:
EMC : EN 61000-6-2, EN 61000-6-3
Safety: EN 61 010-1
Vibration: EN 60068-2-6
Shock: EN 60068-2-27
Pressure (S012 fitting of DN06 to DN65 in PP, PVC, PVDF, brass
or stainless steel): the device can only be used in the following
cases (depending on the max. pressure, the DN of the pipe and
the fluid)
Type of fluid Conditions
Fluid group 1, par. 1.3.a DN 25 only
Type of fluid Conditions
Fluid group 2 par. 1.3.a
DN32
or DN > 32 and PNxDN1000
Fluid group 1 par. 1.3.b PNxDN2000
Fluid group 2 par. 1.3.b DN200
6.3. General technical data
6.3.1. Mechanical data
Component Material
SE12 electronic housing PPS
Cable gland, M12 fixed
connector
PA
Cable, 1 m PVC, T
max
= 80 °C
Seal exposed to the fluid FKM (EDPM on request)
Seal exposed to the ambient air EDPM
Paddle-wheel holder PVDF
Paddle-wheel PVDF
Paddle-wheel axis and
bearings
ceramic
Body of the S012 fitting
stainless steel (316L/DIN1.4404),
brass, PVC, PP, PVDF
Screws Stainless steel A4