Installation and wiring
Type 8012
Install the device on the pipe in such a way that the upstream
and downstream distances are respected according to the
design of the pipes, as per Fig. 4 and the EN ISO 5167-1
standard.
With regulating valve
Pipe with 2 elbows at 90°
in 3 dimensions
Pipe with 2 elbows
at 90°
Pipe with 1 elbow at 90°
or 1 T-piece
With pipe expansion With pipe reduction
50 x DN
5 x DN
40 x DN
5 x DN
25 x DN
5 x DN
20 x DN
5 x DN
18 x DN
5 x DN
15 x DN
5 x DN
Fig. 4 : Upstream and downstream distances depending on the
design of the pipes.
If necessary, use a flow conditioner to improve measurement
precision.
Install the device in such a way that the paddle-wheel axis is
horizontal (Fig. 5).
Prevent the formation of air bubbles in the pipe in the section
around the device (Fig. 6).
Ensure that the pipe is always filled in the section around the
device (Fig. 7).
Correct
Incorrect
Fig. 5 : The paddle-wheel axis must be horizontal
English