Installation and wiring
Type 8012
Correct
Correct
Incorrect
Incorrect
Fluid circulation
direction
Fig. 6 : Air bubbles within the pipe
Correct
Incorrect
Correct
Incorrect
Fig. 7 : Filling the pipe
7.2.2. Installing a device with welding
ends
note
The SE12 electronic module and the seal may be damaged
when welding the connections to the pipe.
Before welding to the pipe, unscrew the 4 locking screws on
the SE12 electronic module.
Remove the electronic module.
Remove the seal.
Follow the installation recommendations in chap. 7.2.2.
Weld the connections.
After welding the connections to the pipe, correctly replace the
seal.
Properly replace the electronic module.
Tighten the 4 screws in an alternating pattern, applying a torque
of 1.5 Nm.