User Manual

7
Technical data
Type 8025/8035 /
6. TECHNICAL DATA
The following technical data are relevant for a 8025 compact or a
8035 and for the remote 8025 connected to a Bürkert flow sensor
8020 / 8030 in a "Low Power" version only.
6.1. Conditions of use
Ambient temperature
8025 compact, 115/230 V AC,
not UR or CSA recognized
8035 compact, 115/230 V AC,
not UR or CSA recognized
other versions, not UR or CSA
recognized
UR and CSA recognized
versions
-10 to 50 °C
-10 to 50 °C
-10 to 60 °C
-10 to 40 °C
Air humidity < 80%, non condensated
Degree of pollution (UR and CSA
recognized versions)
Degree 2 according to EN
61010-1
Installation category (UR and CSA
recognized versions)
Category I according to
UL61010-1
Max. height above sea level 2000 m
Protection rating
8025 compact and 8035
8025 wall-mounted
Housing, panel version
non front parts, panel-mounted
version
According to EN 60529
IP65, device wired and
cable glands tightened and
cover lid screwed tight.
IP65, device wired, cable
glands tightened, cover lid
screwed tight and entry
item nuts of the cable
glands tightened at a
screwing torque of 1.5 Nm.
IP65, installation com-
pleted and closed cabinet
IP20
6.2. Conformity to standards and
directives
The device conforms to the EC directives through the following
standards:
EMC: EN 61000-6-2, EN 61000-6-3, EN 550022
LVD: EN 61010-1
Environnemental testing: Vibration: EN 60068-2-6, Shock:
EN 60068-2-27.
English