User Manual

10
Technical data
Type 8025 /8035 Batch
116
88
88
180
91
21
75
114
105
104
ENTER
0....9
FLOW
Fig. 5: Dimensions of the electronic module SE35 Batch [mm]
Tab. 2: Dimension H [mm] of the dosing controller 8035 Batch,
depending on the DN of the sensor-fitting S030
DN H [mm] with sensor-fitting S030
H
06 134
08 134
15 139
20 137
25 137
32 140
40 144
50 151
65 151
6.5 Electrical data
Power▶source▶(not▶supplied) •▶ limited▶energy▶source▶(in▶
accordance▶to▶UL▶61010-1,▶
paragraph▶9.3)
•▶ or▶Class▶2▶source▶(in▶
accordance▶to▶stan-
dards▶UL▶1310/1585▶and▶
EN▶60950-1)
Power▶supply▶12-36▶V▶DC •▶ filtered▶and▶regulated
•▶ SELV▶circuit,▶with▶a▶safe▶
energy▶level
•▶ max.▶tolerance▶12▶V▶DC:▶-5▶%▶
or▶+10%
•▶ max.▶tolerance▶36▶V▶DC:▶
±10▶%
English