INstallation
Vertical mounting
Correct Incorrect
flow direction
Fig. 10: Filling of the pipe
Correct
flow direction
Incorrect
Correct Incorrect
Fig. 11: Air bubbles within the pipe
→ If necessary, use a flow conditioner to improve measurement
precision.
8.2.2. Installation into the pipe of a 8041
with a G2'' nut
Observe the installation recommendations described at
chap. 8.2.1 and in the operating instructions of the S020.
→ Install the S020 fitting on the pipe.
→ Insert the nut (see mark 3, Fig. 12) on the fitting.
→ Insert the snap ring (mark 2, Fig. 12) into the groove (mark 5,
Fig. 12).
→ Position the cable glands parallel to the pipe and insert the
device (mark 1, Fig. 12) into the fitting.
→ Tighten the nut (mark 3, Fig. 12) by hand on the device.
1
2
3
5
4
Electrodes
Flow direction
Fig. 12: Installation into the pipe of the flowmeter with a G2'' nut
English