Manual

45
Adjustment and commissioning
Briefly press push button.
Press and hold the push
button
Wait for 10 s.
To confirm the selection and go
back to Read mode
To modify the value displayed To go back to Read mode
without confirming the value set.
Go back to Read mode
Go back to Read mode
Release the push button
when desired number of
LEDs is on
C
Fig. 43: Setting the relay switching thresholds, part 3
9.9.3. Viewing and setting the time delay before switching
Switching occurs if one of the thresholds (low, high) is exceeded for a period longer than the set time delay. The time delay applies to both
switching thresholds.
The time delay before switching must be set to between 0 and 100 s. If the time delay is equal to 0, switching occurs immediately.
The time delay before switching is set in 2 steps:
- setting the factors of ten for the seconds;
- setting the seconds.
Viewing and/or setting the time delay before switching (see Fig. 44, Fig. 45 and Fig. 46).
English