User guide

31
Operating and functions
8.6. Details of the Parameters menu
To access the Parameters menu, simultaneously press keys
ENTER
for at least 5 s.
This menu comprises the following configurable parameters:
LANGUAGE
Process level
UNit
K-FACtOR
OUtPUt
iNPUt
FiLtER
tOtAL
FREqUENC.
CUt-OFF
BACKLit
12.6 L/s
END
0......9
Choosing the display language
sAVE N/Y
Choosing the flow rate unit, the number of decimals and the unit the totalizers are
displayed in.
Entering the K factor of the fitting used or have it defined through a teach-in
procedure.
Parameterize the 4-20 mA current output (AO1) and configure the transistor output
(DO1) and, if the device is equipped with, the 2 relay outputs (DO2 and DO3).
Configuring the ON/OFF digital input (DI1), if the device is equipped with.
Choosing the filter level of the measured flow rate, on the displayed flow rate and the
AO1 current output.
Resetting both totalizers.
Setting the electric network frequency.
Entering the measured flow rate value below which the device sets the measured flow
rate to 0 with effect on the display and the outputs.
Setting the brightness of the display and how long it stays ON, or deactivating the
backlight.
Saving the changes made within the Parameters
menu or not. If the changes are saved, the device
operates with the new settings.
Fig. 26: Diagram of the Parameters menu