User Manual

11
Assembly, Installation
Terminal assignment
1
NPN
2
PNP
3
12 - 30 V DC
4
GND
Fig. 3: Terminal assignment of a version with cable gland
Pin assignment
1
12 - 30 V DC
2
NPN
3
GND
4
PNP
Fig. 4: Pin assignment of the M12 male fixed connector
Wire the device following the possibilities described below.
7.2.1. Connection of the flow transmitter
4 - 20 mA
When operating as a flow transmitter,
the NPN and PNP outputs have no
function.
8022
12 - 30 V DC
GND
12 - 30 V DC
Fig. 5: Connection of the flow transmitter
7.2.2. Connection of the pulse divider
The pulse divider type 8022 has 1 NPN pulse output and 1 PNP pulse output. Connect the pulse divider with 3 wires.
English
Type 8022