User Manual

17
Maintenance and troubleshooting
Type 8071
9.4. Dismantle the device
5
4
1
2
3
grooves
Fig. 7: Exploded view of the device
Unscrew the 4 screws (mark 5 Fig. 7) and remove the cover
including the electronic module (mark 4 Fig. 7).
Remove the seal (mark 3 Fig. 7).
Examine the seal for good condition. If not, replace it by a new
one (see chap. "10. Spare parts and accessories").
Remove the rotors (mark 2 Fig. 7).
Examine the rotors for good condition. If necessary, clean or
replace them (see chap. 10).
Warning
Risk of injury due to non-conforming maintenance.
Maintenance must only be carried out by qualified and skilled
staff with the appropriate tools.
Guarantee a set or controlled restarting of the process, after a
power supply interruption.
9.2. Maintenance of the strainer
After the circulation of 200 liters of fluid, examine the strainer for
particles. If necessary clean the strainer with a product compa-
tible with the materials from which it is made.
Regularly examine the strainer for good condition, in particular
when the flow rate decreases. If necessary clean the strainer
with a product compatible with the materials from which it is
made.
9.3. Maintenance of the device
Regularly examine the seal and the oval rotors for good
condition. Follow the instructions on chap. 9.4 et 9.5.
Clean the device with a cloth slightly dampened with water or a
cleaning liquid compatible with the materials the device is made of.
Your Bürkert supplier is at your disposal for any further information.
English