User Manual

19
Maintenance and troubleshooting
Type 8071
9.6. If a problem occurs
Problem Cause Solution
Fluid does not
flow through the
device any more
Obturated device
Remove and clean the oval rotors (see chap. "9.4. Dismantle the device" and
"9.5. Assemble the device").
Add a strainer of 75 µm upstream of the device.
Obturated strainer (if present)
Clean the strainer.
Rotors damaged
Replace the rotors (see chap. "10. Spare parts and accessories", "9.4. Dis-
mantle the device" and "9.5. Assemble the device").
Reduced flow
rate through the
device
Strainer (if present) partially obturated
Clean the strainer.
Fluid too viscous Use rotors for fluids with a viscosity > 1000 mPa.s.
Incoherent
measurement
Flow rate range not adapted
Verify specifications, adjust the device or the flow rate (see chap. "6.2.2.
General data").
Air within the pipe
Slowly drain air from the pipe.
Friction due to an incorrect assembly
of the device
Verify the assembly of the rotors in the fitting (see chap. "9.4. Dismantle the
device" and chap. "9.5. Assemble the device").
No frequency
output
Incorrect wiring of the outputs
Make sure that the device has been wired correctly (see chap. "7.3. Wiring").
Rotors incorrectly mounted
Dismantle the device and modify the position of the rotors (see "9.4. Dismantle
the device" and "9.5. Assemble the device").
Magnet damaged
Replace the rotors (see chap. "10. Spare parts and accessories", "9.4. Dis-
mantle the device" and "9.5. Assemble the device").
Hall sensor or Reed switch defective
Replace the cover with electronic module (see chap. "10. Spare parts and
accessories", 9.4 and 9.5).
English