Technical data
Measurement range
8032
8072
0.3 m/s to 10 m/s,
0.3 m/s corrresponds to a flow
rate of 0.5 l/min in a DN06
fitting
2 to 1200 l/min, with a vis-
cosity > 5 cps;
3 to 616 l/min, with a viscosity
< 5 cps;
Accuracy
8032 (see
Fig. 7)
8072
±1 % of the full scale
1)
, with
on site calibration or when
using the teach-in feature
or
± (1 % of the full scale
1)
+ 3%
of the measured value), when
using the standard K factor
±1% of the measured value
Repeatability
8032
8072
±0.4% of the measured value
±0.03% of the measured
value
Linearity (8032 only) ±0.5 % of the full scale
1)
Measuring element paddle-wheel of the S030 fitting
or oval gears of the S070 fitting
1)
Full scale = 10 m/s
Type of fluid depends on the fitting used
(refer to the operating instruc-
tions of the fitting used)
Fluid viscosity depends on the fitting used
(refer to the operating instruc-
tions of the fitting used)
Rate of solid particles (8032
only)
max. 1%
Fluid temperature
with fitting S030 in PVC
with fitting S030 in PP
with fitting S030 in stainless
steel, PVDF, or brass
with S070 fitting, housing in
aluminium
with S070 fitting, housing in
stainless steel
0 to 50 °C (see Fig. 8)
0 to 80 °C (see Fig. 8)
-15 to 100 °C (see Fig. 8)
max. 80 °C
max. 100 °C
Fluid pressure
8032 with S030 fitting in
metal
8032 with S030 fitting in
plastic
8072 with fitting S070 with
flanges
8072 with any fitting S070
except S070 with flanges
PN16 max. (see Fig. 8)
PN10 max. (see Fig. 8)
PN10 max.
PN55 max.
English