Owner's manual
33
Adjustment and functions
9.5.2. Entering the K factor or having it determined by teach-in
During the whole teach-in procedure, the outputs are frozen to the status they had at the start of the teach-in.
ENTER
0......9
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
0......9
0......9
*
*
KFAC
NO
TEAC
YES
TEAC
49.03
KFAC
TEAC
200.0
VOL
49.03
KFAC
To function OUT
* to move the decimal point, simultaneously press keys
0......9
and
• Entering the K factor of the fitting used:
→ select "NO TEAC",
→ press key "ENTER",
→ In the KFAC parameter, enter the K factor of the
fitting used, in pulse/litre (value between 0,001 and
9999). Find the K factor within the operating instruc-
tions of the fitting.
• Determining the K factor by means of a teach-in
procedure:
→ install the 8032 / 8072 in series with a valve, for
instance, then
→ fill a tank with x litres capacity (200 litres for
example).
→ select "YES TEAC",
→ press key "ENTER",
→ open the valve: message "TEAC" blinks.
→ when the tank if full, press again key "ENTER".
→ enter the volume of liquid that has passed through
the circuit (in the unit displayed alternately with the
message "VOL"): the device calculates the K factor
and displays it.
English
Adjustment and functions