9.5.2. Entering the K factor or having it determined by teach-in
During the whole teach-in procedure, the outputs are frozen to the status they had at the start of the teach-in.
ENTER
0......9
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
0......9
0......9
*
*
KFAC
NO
TEAC
YES
TEAC
49.03
KFAC
TEAC
200.0
VOL
49.03
KFAC
To function OUT
* to move the decimal point, simultaneously press keys
0......9
and
Entering the K factor of the fitting used:
select "NO TEAC",
press key "ENTER",
In the KFAC parameter, enter the K factor of the
fitting used, in pulse/litre (value between 0,001 and
9999). Find the K factor within the operating instruc-
tions of the fitting.
Determining the K factor by means of a teach-in
procedure:
install the 8032 / 8072 in series with a valve, for
instance, then
fill a tank with x litres capacity (200 litres for
example).
select "YES TEAC",
press key "ENTER",
open the valve: message "TEAC" blinks.
when the tank if full, press again key "ENTER".
enter the volume of liquid that has passed through
the circuit (in the unit displayed alternately with the
message "VOL"): the device calculates the K factor
and displays it.
English