Description
frequency proportional to the flow rate (f = KxQ, f is the frequency in Hz, K the proportionality factor, called K factor, in pulse/litre, which is
specific to each S030 fitting, and Q is the flow rate in l/s).
• The device 8072 detects the rotation of the oval gears of the S070 fitting. The oval gears generate a measuring signal with a frequency
proportional to the flow rate. The proportionality factor, called K factor, is specific to each S070 fitting.
5.3. Available versions of the SE32 electronic module
The order codes of the S030 or S070 fittings can be taken from the related data sheet: refer to the data sheets to select the fitting suited to
your application.
SE32 version
Supply
voltage
Output Electrical connection UL Order code
Threshold
detector
12-36 V DC Transistor, NPN EN 175301-803 male fixed connector
no 436474
Threshold
detector
12-36 V DC Transistor, PNP EN 175301-803 male fixed connector
no 434871
Threshold
detector
12-36 V DC Transistor, NPN
and PNP
Male 5-pin M12 fixed connector
no 436473
yes 553431
Threshold
detector
12-36 V DC Relay Male 5-pin M12 and male EN 175301-803 fixed connectors
no 436475
Flowmeter 12-36 V DC 4-20 mA + Relay Male 8-pin M12 and male EN 175301-803 fixed connectors
no 560547
Flowmeter 12-36 V DC 4-20 mA + Relay Male 5-pin M12 and male EN 175301-803 fixed connectors no 560402
Flowmeter 12-36 V DC 4-20 mA Male 5-pin M12 fixed connector no 560403
English