Type 8026 - 8036 - 8076 Flowmeters and Flow transmitters Durchfluss-Messgerät oder Durchfluss-Transmitter Débitrmètres et transmetteurs de débit Operating Instructions Bedienungsanleitung Manuel d‘utilisation
We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modification technique.
Type 8026- 8036- 8076 1. About this manual......................................................................................................................................................................4 1.1. Symbols used...........................................................................................................................................................................4 1.2. Definition of the word "device".....................................................................
Type 8026- 8036- 8076 8. 7.3. Mounting the cover.............................................................................................................................................................22 7.4. Mounting the display module........................................................................................................................................22 7.5. Dismounting the display module.........................................................................................
Type 8026- 8036- 8076 9.12.3. Restoring the default parameters of the Process level and the outputs.....................................48 9.12.4. Setting the data displayed on lines 1 and 2 of the display module..............................................48 9.12.5. Choosing the units for the totalizers displayed in Process level...................................................50 9.12.6. Displaying the lowest and highest values measured.................................................................
Type 8026- 8036- 8076 About this manual 1. About this manual This manual describes the entire life cycle of the device. Please keep this manual in a safe place, accessible to all users and any new owners. This manual contains important safety information. Failure to comply with these instructions can lead to hazardous situations. • This manual must be read and understood. 1.1. Symbols used danger Warns against an imminent danger.
Type 8026- 8036- 8076 Intended use 2. Intended use Use of the device that does not comply with the instructions could present risks to people, nearby installations and the environment. • 8026, 8036 and 8076 devices are intended to measure the flow rate of liquids: -- 8026 and 8036 flowmeters are used to measure the flow of neutral or slightly aggressive liquids, -- 8076 flowmeters are used to measure the flow rate of viscous liquids such as honey or oil, which are free of solid particles.
Type 8026- 8036- 8076 Basic safety information 3. Basic safety information This safety information does not take into account: • any contingencies or occurences that may arise during installation, use and maintenance of the devices. • the local safety regulations for which the operating company is responsible including the staff in charge of installation and maintenance. Danger due to high pressure in the installation.
Type 8026- 8036- 8076 Basic safety information note The device may be damaged by the fluid in contact with. • Systematically check the chemical compatibility of the component materials of the device and the fluids likely to come into contact with it (for example: alcohols, strong or concentrated acids, aldehydes, alkaline compounds, esters, aliphatic compounds, ketones, halogenated aromatics or hydrocarbons, oxidants and chlorinated agents).
Type 8026- 8036- 8076 General information 4. General information 4.1. Manufacturer's address and international contacts To contact the manufacturer of the device, use following address: Bürkert SAS Rue du Giessen BP 21 F-67220 TRIEMBACH-AU-VAL You may also contact your local Bürkert sales office. The addresses of our international sales offices are available on the internet at: www.burkert.com 4.2.
Type 8026- 8036- 8076 Description 5. Description 5.1. Area of application 8026, 8036 and 8076 devices are intended to measure the flow rate of liquids: • 8026 and 8036 flowmeters are used to measure the flow of neutral or slightly aggressive liquids, • 8076 flowmeters are used to measure the flow rate of viscous liquids such as honey or oil, which are free of solid particles.
Type 8026- 8036- 8076 Description 5.2.2. Construction of the 8036 The 8036 flowmeter comprises: A: an S030 fitting including the paddle-wheel flow sensor. C B Set in rotation by the flow, the 4 permanent magnets integrated in the vanes of the paddle generate pulses, the frequency of which is proportional to the flow speed of the fluid. A conversion coefficient specific to each pipe (material and diameter) is necessary to establish the flow rate value associated with the measurement.
Type 8026- 8036- 8076 Description Description of the name plate Made in France 5.3. 8026 Flow-Meter Supply: 14-36VDC Output: 1x4-20mA 2xTransistors 500 mA Max Cell: HALL INSERTION SHORT Process: Temp -15/100°C PN 10 Bar 11 IP67 10 9 S-N:1110 W49LU 2:NPN/PNP1 3:0V 00560861 1 2 3 4 5 6 1:V+ 7 4:NPN/PNP2 8 Figure 1 : Example of a name plate 1. Type of the device and measured varaible 2. Power supply 3. Output specifications 4. Type of sensor 5. Fluid temperature range 6.
Type 8026- 8036- 8076 Description 5.4. Available versions of type 8026 The following versions of the 8026 flowmeter are available. Each version of the 8026 flowmeter is available without or with the display module.
Type 8026- 8036- 8076 Description 5.5. Available versions of the electronic module SE36 The following versions of the electronic module SE36, part of the flowmeter 8036 or 8076 are available. The references of the S030 and S070 fittings including the flow sensor can be found on the relevant technical data sheets for these product types. Each version of the electronic module is available without or with the display module.
Type 8026- 8036- 8076 Technical data 6. Technical data 6.1. Conditions of use Ambient temperature -10 to +60 °C Air humidity < 85%, non condensated Protection rating IP67 and IP65 with connectors plugged in and tightened and electronic module cover fully screwed down 6.2. Conformity to standards and directives 6.2.1.
Type 8026- 8036- 8076 Technical data 6.3. General technical data 6.3.1. Mechanical data Part Box / seals Material stainless steel 1.4404, PPS / EPDM Cover / seal PC / EPDM Display module PC / PBT M12 fixed connector nickel-plated brass Fixed connector holder stainless steel 1.
Type 8026- 8036- 8076 H Technical data 140 131 DN H [mm] 06 08 15 20 25 32 40 50 65 with fitting S030 160 160 165 163 163 166 170 177 177 H 70 97 DN 15 25 40 50 80 100 Figure 3 : H [mm] with fitting S070 166 181 198 216 256 257 Dimensions of the electronic module SE36 and dimension H of flowmeters 8036 and 8076 16 English
Type 8026- 8036- 8076 H Technical data 97 Ø 65 70 230 / 268,5 1) 151 DN of the fitting [mm] Ø 75 Ø 26,5 1) with short sensor / with long sensor Figure 4 : 15 20 25 32 40 50 65 80 100 110 125 150 180 200 250 300 350 400 H [mm] with fitting S020 type: T-fitting Flange fitting 231.5 229.5 229.5 232.5. 236.5 242.5 242.5 267.5 265.5 270.5 275.5 271.5 278.5 248.5 312.5 324.5 Plastic spigot Spigot or welding tab in stainless steel 250.5 256.5 263.5 237.5 243.5 248.5 258.5 298.5 305.5 269.
Type 8026- 8036- 8076 Technical data P (bar) 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 A Metal (PN16) PVDF PVC + PP PVDF (PN10) PVC (PN10) PP (PN10) -10 +10 +30 +50 +70 +90 +110 T (°C) A: Operating range Figure 6 : Fluid temperature-pressure dependency for the flowmeter 8036 (SE36 associated to a fitting S030 with PVDF paddle wheel) 6.3.2.
Type 8026- 8036- 8076 Technical data Fluid pressure Also refer to the requirements of the Pressure Directive: see chap. 6.2.2 • 8026 • PN10; Also factor in the fluid temperature/pressure dependency for the 8026 inserted into an S020 fitting (see Figure 5) • 8036 • PN16; Also factor in the fluid temperature/pressure dependency for the 8036 (SE36 mounted on an S030 fitting): see Figure 6 • 8076 with a fitting S070 of DN15 • max. 55 bar • 8076 with a fitting S070 of DN25 • max.
Type 8026- 8036- 8076 Technical data Specifications of the power source (not supplied) of the UL devices • limited energy source (in accordance to UL 61010-1, paragraph 9.3) • or Class 2 source (in accordance to standards 1310/1585 and 60950-1) Current consumption • version with 2 or 3 outputs (2 wires) • 25 mA max.
Type 8026- 8036- 8076 Assembly 7. Assembly 7.1. Safety instructions danger Risk of injury due to electrical voltage. • Shut down and isolate the electrical power source before carrying out work on the system. • Observe all applicable accident protection and safety regulations for electrical equipment. Warning Risk of injury due to non-conforming assembly. • The device must only be assembled by qualified and skilled staff with the appropriate tools.
Type 8026- 8036- 8076 Assembly 7.3. Mounting the cover →→Check that there is a seal on the cover and that it is not damaged. Replace it if necessary. →→Grease the seal if necessary, using a component compatible with the seal material. →→Fully tighten by hand to guarantee tightness. Figure 8 : Fitting the cover 7.4. Mounting the display module →→Unscrew the cover (see chapter 7.2). 20° →→Set the display module at an angle of ca. 20° in relation to the desired position.
Type 8026- 8036- 8076 Assembly 7.5. Dismounting the display module →→Unscrew the cover if necessary (see chapter 7.2). →→Turn the module by ca. 20° to the left. Once unlocked, the module is raised slightly by the spring action. 20° →→Remove the module from its housing.
Type 8026- 8036- 8076 Installation and wiring 8. Installation and wiring 8.1. Safety instructions danger Risk of injury due to high pressure in the installation. • Stop the circulation of fluid, cut off the pressure and drain the pipe before loosening the process connections. Risk of injury due to electrical voltage. • Shut down and isolate the electrical power source before carrying out work on the system. • Observe all applicable accident protection and safety regulations for electrical equipment.
Type 8026- 8036- 8076 Installation and wiring 8.2.1. Recommendations on installing an 8026 or an 8036 on a pipe attention Risk of damage when installing the fitting. • Respect the installation instructions given in the user manual for the fitting. →→Install the fitting on the pipe, respecting the instructions given in the manual for the fitting used. →→Respect the following additional conditions of installation to ensure that the device operates correctly (Figure 11 and Figure 12).
Type 8026- 8036- 8076 Installation and wiring →→1: Insert the electronic module in the sensor holder. →→2: Turn the electronic module by a quarter turn. SE36 1 →→3: Secure the electronic module and the S030 fitting only, by 2 S030 tightening the screw with a suitable tool to a max. tightening torque of 1 Nm. 3 1 SE36 2 S070 Figure 13 : Assembling the SE36 and the fitting S030 or S070 →→Check that there is a seal on the fitting and that it is not damaged. Replace the seal if necessary.
Type 8026- 8036- 8076 Installation and wiring Correct Figure 15 : Incorrect The oval gear axes must be horizontal (seen from the front) →→Fit the display module (see chap. 7.4) to parameter the device. →→Assemble flowmeter type 8076 (see Figure 13) →→Set the K factor parameter (see chap. 9.13.5) or have it determined through a teach-in procedure. 8.3. Wiring danger Risk of injury due to electrical voltage. • Shut down and isolate the electrical power source before carrying out work on the system.
Type 8026- 8036- 8076 Installation and wiring →→Strip 20 mm of the cable. 5 5,5 →→Cut the central wire (earth) so that its length is equal to 11.5 mm. ,5 11 20 →→Expose 5.5 mm of the wires on the stripped cable. →→Insert each wire into the appropriate pin on the terminal block [5] (see chap. 8.3.4 to chap. 8.3.6). →→Tighten the terminal block [5] wired to the body [4]. →→Tighten the connector nut [1]. Figure 16 : Multipin M12 connector (available as an accessory) 8.3.3.
Type 8026- 8036- 8076 Installation and wiring 8.3.4.
Type 8026- 8036- 8076 Installation and wiring Load white 2 blue 3 brown 4 1 grey - + 4-20 mA input (external instrument) - + Power supply 14-36 VDC Figure 22 : Wiring the NPN transistor output and the current output in sinking mode (parameter setting "NPN/sink", cannot be changed), on a version with 1 M12 fixed connector, 1 NPN transistor output and 1 current output 8.3.5.
Type 8026- 8036- 8076 Installation and wiring Load 1 (solenoid valve for instance) white 2 black 3 Load 2 (solenoid valve for instance) Figure 24 : 4 1 brown grey blue - + Power supply 14-36 V DC NPN wiring of both transistor outputs (parameter setting "NPN/sink"), of a version with 1 M12 fixed connector Load 1 (solenoid valve for instance) white 2 black 3 1 brown grey blue Load 2 (solenoid valve for instance) Figure 25 : 4 - + Power supply 14-36 V DC PNP wiring of both transisto
Type 8026- 8036- 8076 Installation and wiring Load 1 white blue 2 black 3 4 1 - + 4-20 mA input (external instrument) - + Power supply brown grey Load 2 14-36 V DC Figure 28 : PNP wiring of both transistor outputs and wiring the current output in sourcing mode (parameter setting "PNP/ source"), of a version with 1 M12 fixed connector 8.3.6.
Type 8026- 8036- 8076 Installation and wiring Load 1 (solenoid valve for instance) white white 2 2 brown 3 blue Load 2 (solenoid valve for instance) 4 1 1 grey 3 4 blue Power supply - + 12-36 V DC Figure 31 : PNP wiring of both transistor outputs (parameter setting "PNP/source"), of a version with 2 M12 fixed connectors 1st 4-20 mA input (external instrument) - + 2nd 4-20 mA input (external instrument) - + 2 3 black 4 brown 1 brown grey black blue Power supply 2 1 4 3 - + 1
Type 8026- 8036- 8076 Installation and wiring Load 1 Load 2 white white 2 black 3 4 1 1 - + 3 4 black grey blue 1st 4-20 mA input (external instrument) 2 brown brown - + - + 12-36 V DC 2nd 4-20 mA input (external instrument) Power supply Figure 34 : NPN wiring of both transistor outputs and wiring of both current outputs in sinking mode, on a version with 2 fixed connectors (parameter setting "NPN/sink") Load 2 Load 1 white white 2 blue 3 black 4 1 brown 2 1 4 3 blue grey
Type 8026- 8036- 8076 Adjustment and commissioning 9. Adjustment and commissioning 9.1. Safety instructions Warning Risk of injury due to non-conforming adjustment. Non-conforming operating could lead to injuries and damage the device and its surroundings. • The operators in charge of adjustment must have read and understood the contents of this manual. • In particular, observe the safety recommendations and intended use. • The device/installation must only be adjusted by suitably trained staff.
Type 8026- 8036- 8076 Adjustment and commissioning 9.3.
Type 8026- 8036- 8076 Adjustment and commissioning 9.4. Using the navigation button Symbolised by this manual in Symbolised by this manual in Symbolised by this manual Symbolised by this manual Symbolised by this manual Figure 37 : in in in Using the navigation button You want to... ...browse in Read level Press... • next screen: • previous screen: • ...display the Param menu • ...access the Configuration level for at least 2 sec., from any screen of the Read level ...
Type 8026- 8036- 8076 Adjustment and commissioning You want to... ...browse in the dynamic functions bar (MEAS, BACK, ABORT, OK, YES, NO) Press... • next function: • previous function: ...confirm the highlighted dynamic function ...
Type 8026- 8036- 8076 Adjustment and commissioning 9.6. Example for the input of a numerical value Modify each digit of the numerical value using: AC1 4mA This is where the device is being parametered............ .................... +0.000l/h MEAS ABORT OK Dynamic functions (accessible through 9.7. - to increase the digit selected, - to decrease the digit selected.
Type 8026- 8036- 8076 Adjustment and commissioning 9.8. Description of icons and LEDs • The LEDs of the display module are duplicated on the electronic board that is located under the display module: these LEDs become visible when the device is not equipped with the display module. • The yellow LED related to a transistor output is deactivated if the transistor output is configured in pulse mode ("Pulse").
Type 8026- 8036- 8076 Adjustment and commissioning 9.9. Process level A First view of the Process level. Zoom on the value in the first line. Zoom on the value in the second line. Display of the main volume totalizer. Display of the second volume totalizer. Flow_L 1243l/h 1) 2) Flow_m3 1. 243/h 1) Flow_L 1243l/h Flow_m3 1.243/h B Display of the minimum and maximum input flows or frequencies measured. Display of the current outputs. Max Min AC1 AC2 3) 1250l/h Reset Yes/No 1200l/h 18.
Type 8026- 8036- 8076 Adjustment and commissioning 9.10. Accessing the Configuration level This is when the device is being parametered............ .................... This is when the device is being parametered............ .................... Param Parameters Menu Calib Wrong code This is when the device is being parametered............ .................... > 2s Any view of the Process level Calibration Menu This is when the device is being parametered............ ...............
Type 8026- 8036- 8076 Adjustment and commissioning 9.11. Structure of the Configuration menus See chap. 9.10 to access the Configuration level. Param This is when the device is being parametered............ .................... System Display This is when the device is being parametered............ .................... This is when the device is being parametered............ .................... Download Downl.
Type 8026- 8036- 8076 Adjustment and commissioning Param This is when the device is being parametered............ .................... Outputs This is when the device is being parametered............ .................... HWMode sink/NPN source/PNP AC1 / AC2 PVar: On a version with 2 transistor outputs Flow_L Flow_m3 Flow_gal Flow_Igal Freq. Tot1_L Tot1_m3 Tot1_gal Tot1_Igal Tot2_L Tot2_m3 Tot2_gal Tot2_Igal 4mA: INPUT 20mA: INPUT Filter: Slow Fast None Diag.
Type 8026- 8036- 8076 Adjustment and commissioning Calib System Hold Hold: Disable Hold: Enable Outputs Sensor Code 0*** Total 1 Reset Yes/No Total 2 Reset Yes/No AC1 / AC2 4mA: INPUT 20mA: INPUT K.fact. INPUT Vol.Teach PVar: Confirm 0*** Litre m3 gal Igal Start Teach Meas.Progress Input Vol. Cal. Result Flow Teach PVar: Flow_L Flow_m3 Flow_gal Flow_Igal Freq. Start Teach Measure Flow Teach Cal.
Type 8026- 8036- 8076 Adjustment and commissioning Test System Code 0*** Confirm Outputs AC1 AC1 Simul: INPUT AC2 Sensor AC2 Simul: INPUT TR1 TR1 Simul: OFF/ON TR2 TR2 Simul: OFF/ON PVar: 0*** Flow_L Flow_m3 Flow_gal Flow_Igal Freq. Tot1_L Tot1_m3 Tot1_gal Tot1_Igal Tot2_L Tot2_m3 Tot2_gal Tot2_Igal Value: Info Error E:MESSAGE Warning W:MESSAGE Smiley MESSAGE Software Main Sensor 9.12. INPUT Soft.Main Not set Parameters Menu 9.12.1.
Type 8026- 8036- 8076 Adjustment and commissioning The data transfer is impossible from a device having an acquisition / conversion module for the process values measured with a V2 software version to a device having an acquisition / conversion module for the process values measured with a V1 software version. • On each device, check the software version of the acquisition / conversion module for the process values measured, in the menu "Info -> Software -> Versions -> Main".
Type 8026- 8036- 8076 Adjustment and commissioning 9.12.2. Modifying the PARAM menu access code See chap. 9.10 to access the Param menu. The default access code is "0000". Param Code System This is when the device is being parametered............ .................... 0*** Confirm Enter the new access code to the PARAM menu This is when the device is being parametered............ .................... 0*** Confirm the new code 9.12.3.
Type 8026- 8036- 8076 Adjustment and commissioning UNIT: Choose the preferred time unit in which the flow rate is displayed. Take care to choose the time unit according to the flow rate in the pipes as the display indicates a maximum flow rate of 9999 volume units/time unit. • If the flow rate measured is 0 ≤ volume unit/h ≤ 9999, choose the time unit “/h” so that the display indicates a flow rate in volume units/h.
Type 8026- 8036- 8076 Adjustment and commissioning 30 s t "slow" Figure 39 : 6s t t 150 ms "fast" "none" filter Filter curves 9.12.5. Choosing the units for the totalizers displayed in Process level See chap. 9.10 to access the Param menu. The totalizers are saved if a power cut occurs. Display Param This is when the device is being parametered............ .................... Totalizers Total1 / Total 2 Unit Liter m3 This is when the device is being parametered............ ................
Type 8026- 8036- 8076 Adjustment and commissioning 9.12.7. Setting the parameters for the reading comfort level of the data displayed See chap. 9.10 to access the Param menu. Display Param This is when the device is being parametered............ .................... This is when the device is being parametered............ .................... Set each percentage using Contrast xx% Backlight xx% and . CONTRAST: Choose the display contrast level (as a %).
Type 8026- 8036- 8076 Adjustment and commissioning Param Outputs This is when the device is being parametered............ .................... AC1 / AC2 PVar: Flow_L Flow_m3 This is when the device is being parametered............ .................... Flow_gal Flow_Igal Freq. Tot1_L Tot1_m3 Tot1_gal Tot1_Igal Tot2_L Tot2_m3 Tot2_gal Tot2_Igal 4mA: INPUT 20mA: INPUT Filter: Slow Fast None Diag.
Type 8026- 8036- 8076 Adjustment and commissioning See also "If you encounter problems" in chap. 10.3 9.12.10. Setting the parameters of the transistor outputs See chap. 9.10 to access the Param menu. The 2nd transistor output "TR2" is only available on a version with 2 transistor outputs. Outputs Param This is when the device is being parametered............ .................... TR1 / TR2 PVar: Flow_L Flow_m3 This is when the device is being parametered............ ....................
Type 8026- 8036- 8076 Adjustment and commissioning Switching only occurs if one of the thresholds, high or low (functions "High" or "Low"), is exceeded for a duration longer than this time delay. PULSE: When the choice “Pulse” is selected in MODE function above, enter here the volume of fluid for which a pulse must be transmitted on transistor output 1 or transistor output 2 respectively.
Type 8026- 8036- 8076 Adjustment and commissioning 9.13. Calibration menu 9.13.1. Activating/deactivating the Hold function See chap. 9.10 to access the Calib menu. Calib System Hold Hold: Disable Hold: Enable The Hold mode is automatically deactivated when the device restarts after a power interruption, if the Hold mode was activated at the moment of the power cut-off. The Hold mode is used to carry out maintenance work without interrupting the process.
Type 8026- 8036- 8076 Adjustment and commissioning 9.13.3. Resetting totalizer 1 or totalizer 2 respectively See chap. 9.10 to access the Calib menu. Calib System Total 1 Reset Yes/No Total 2 Reset Yes/No TOTAL 1 or TOTAL 2 respectively: Reset (choice “Yes”) or do not reset (choice “No”) totalizer 1 or totalizer 2 respectively. Totalizer 2 can be reset from Process level. See chap. 9.9. 9.13.4. Adjusting the current outputs Warning Risk of injury due to wrong adjustment.
Type 8026- 8036- 8076 Adjustment and commissioning 9.13.5. Entering the K factor or determining it with Teach-in See chap. 9.10 to access the Calib menu. Calib Sensor K.fact. INPUT Vol.Teach PVar: Litre m3 gal Igal Start Teach Meas.Progress Input Vol. Cal. Result Flow Teach PVar: Flow_L Flow_m3 Flow_gal Flow_Igal Freq. Start Teach Measure Flow Teach Cal. Result K.FACT.: Enter the K factor of the fitting used. VOL.
Type 8026- 8036- 8076 Adjustment and commissioning →→Run the teach-in: Calib Sensor Vol.Teach Start Teach →→Open the valve to fill the tank. OK Meas. Progr. 2.001 l/s The device displays the instantaneous flow of the fluid. →→When the tank is filled, close the valve. OK The device displays the volume calculated with the current K factor. If the display shows “++++”, the volume calculated > 9999 volume units: continue the procedure as normal. The device displays the K factor calculated by teach-in.
Type 8026- 8036- 8076 Adjustment and commissioning Detailed procedure of a Teach-in by flow rate (“Flow.Teach” function in the “Sensor” menu) →→Choose the volume unit in which the teach-in is run: Calib Sensor Flow Teach Flow_L PVar: Flow_m3 Flow_gal Flow_Igal Freq. →→Run the teach-in: Calib Sensor →→Establish the flow in the pipe and wait until it is Flow Teach stabilised. Start Teach OK The bargraph shows the time passed.
Type 8026- 8036- 8076 Adjustment and commissioning 9.14. Diagnostic menu 9.14.1. Modifying the Diagnostic menu access code See chap. 9.10 to access the Diagnostic menu. The default access code is "0000". System Diagnostic Code 0*** Confirm 0*** Enter the new access code to the DIAGNOSTIC menu Confirm the new code 9.14.2. Monitoring the sensor input frequency See chap. 9.10 to access the Diagnostic menu.
Type 8026- 8036- 8076 Adjustment and commissioning When the device generates a "warning" or "error" event: →→go into the "Info" menu to read the cause of the event generation. →→and/or go into the "Sensor" function of the Diagnostic menu to read the measured input frequency. →→if necessary, clean the paddle or the oval gears. →→if necessary, check the process. • The "warning" event may also be associated with one or other or both transistor outputs. See chap. 9.12.9, function "Output.TR1" or "Output.TR2".
Type 8026- 8036- 8076 Adjustment and commissioning 9.15.3. Checking the outputs behaviour See chap. 9.10 to access the Test menu. The feature allows for simulating the measurement of the physical parameter or the value of the totalizer to check if the outputs are correctly configured. The T icon is displayed in place of the icon as soon as the check for the correct working of an output has started. During the check the related output does not react according to the measured physical value.
Type 8026- 8036- 8076 Maintenance and troubleshooting 10. Maintenance and troubleshooting 10.1. Safety instructions danger Risk of injury due to high pressure in the installation. • Stop the circulation of fluid, cut off the pressure and drain the pipe before loosening the process connections. Risk of injury due to electrical voltage. • Shut down and isolate the electrical power source before carrying out work on the system.
Type 8026- 8036- 8076 Maintenance and troubleshooting Red LED Current Transistor output output ON 22 mA 1) depending on thresholds Icon ERR + Message displayed in the Info menu "TR EE Fact Read" Possible cause Recommended action Parameter reading error. →→Switch the power supply off then on again. →→If the error persists, set the "TR EE User Read" device back to the default settings (chap. 9.12.3). →→If the error persists, return the device to Bürkert.
Type 8026- 8036- 8076 Maintenance and troubleshooting Red LED Current Transistor output output OFF 4-20 mA Switched 2) Icon Message displayed in the Info menu "W:TRnPu 1:1 set" Possible cause Recommended action In “Pulse” mode, the volume entered for a pulse is incorrect (see chap. 9.12.10). →→Enter an appropriate volume. →→check the K factor. 1) if the DIAG MODE function of the "Output.AC1" or "Output.AC2" menu is set to "22 mA" (see chap. 9.12.
Type 8026- 8036- 8076 Spare parts and accessories 11. Spare parts and accessories attention Risk of injury and/or damage caused by the use of unsuitable parts. Incorrect accessories and unsuitable replacement parts may cause injuries and damage the device and the surrounding area. • Use only original accessories and original replacement parts from Bürkert.
Type 8026- 8036- 8076 Spare parts and accessories 14. Disposal of the product →→Dispose of the device and its packaging in an environmentally-friendly way. note Damage to the environment caused by products contaminated by fluids. • Keep to the existing provisions on the subject of waste disposal and environmental protection. note Comply with the national and/or local regulations which concern the area of waste disposal.
Type 8026- 8036- 8076 Spare parts and accessories 68 English
www.burkert.