Instruction Manual

12
Description
5.4. Available versions of type 8026
The following versions of the 8026 flowmeter are available. Each version of the 8026 flowmeter is available
without or with the display module.
The display module is also available as an accessory. See chap. 11.
Voltage supply
Outputs
Electrical connection
Type of sensor
Seal of the sensor
UL
Type of connection of
the outputs
Order code of the
8026
without
display
module
with display
module
14-36 V DC 1 NPN transistor +
1 x 4-20 mA
Male 5-pin M12
fixed connector
Short FKM
1)
no 2-wire
560860 561860
Long FKM
1)
560870 561870
Short FKM
1)
yes 2-wire
560863 561863
Long FKM
1)
560873 561873
2 x transistor,
NPN/PNP, + 1 x
4-20 mA
Male 5-pin M12
fixed connector
Short FKM
1)
no 2-wire
560861 561861
Long FKM
1)
560871 561871
Short FKM
1)
yes 2-wire
560864 561864
Long FKM
1)
560874 561874
12-36 V DC 2 x transistor,
NPN/PNP, + 2 x
4-20 mA
Male 5-pin M12
fixed connector +
female 5-pin M12
fixed connector
Short FKM
1)
no 3-wire
560862 561862
Long FKM
1)
560872 561872
Short FKM
1)
yes 3-wire
560865 561865
Long FKM
1)
560875 561875
1)
A set with additional seals (1 green FKM seal + 1 black EPDM seal) is delivered with each device.
English