Instruction Manual

13
Description
5.5. Available versions of the electronic module SE36
The following versions of the electronic module SE36, part of the flowmeter 8036 or 8076 are available. The
references of the S030 and S070 fittings including the flow sensor can be found on the relevant technical data
sheets for these product types.
Each version of the electronic module is available without or with the display module.
The display module is also available as an accessory. See chap. 11.
Voltage supply
Outputs
Electrical connection
Type of connection of the
outputs
UL
Order code of the SE36
without
display
module
with display
module
14-36 V DC 1 NPN transistor
+ 1 x 4-20 mA
Male 5-pin M12
fixed connector
2-wire no
560880 561880
yes
560883 561883
2 x transistor,
NPN/PNP, + 1 x
4-20 mA
Male 5-pin M12
fixed connector
2-wire no
560881 561881
yes
560884 561884
12-36 V DC 2 x transistor,
NPN/PNP, + 2 x
4-20 mA
Male 5-pin M12
fixed connector +
female 5-pin M12
fixed connector
3-wire no
560882 561882
yes
560885 561 885
English