Instruction Manual

19
Technical data
Fluid pressure
8026
8036
8076 with a fitting S070 of DN15
8076 with a fitting S070 of DN25
8076 with a fitting S070 of DN40 or DN50
8076 with a fitting S070 of DN80
8076 with a fitting S070 of DN100
Also refer to the requirements of the Pressure Directive: see
chap. 6.2.2
PN10; Also factor in the fluid temperature/pressure
dependency for the 8026 inserted into an S020 fitting (see
Figure 5)
PN16; Also factor in the fluid temperature/pressure
dependency for the 8036 (SE36 mounted on an S030 fitting):
see Figure 6
max. 55 bar
max. 55 bar (or the rules governing the flanges)
• max. 18 bar
max. 12 bar
max. 10 bar
Type of fluid
8026 and 8036
8076
• Neutral or slightly aggressive fluids
• Viscous fluids, free of solid particles
Fluid viscosity
8026 and 8036
8076
• 300 cSt max.
• Refer to the operating manual for fitting S070
Solid particle rate in the fluid
8026 and 8036
8076
1%
• 0 %
Flow rate measurement
Measurement range
Linearity
Repeatability
Measurement error with standard K factor
measurement error with a Teach-in
procedure
0,3 to 10 m/s
• ±0,5%
2)
of the full scale
• ±0,4%
2)
of the measured value
±2,5%
2)
of the measured value
±1%
2)
of the measured value (at the teach-in point)
1)
and PVDF paddle wheel
2)
Determined in the following reference conditions: fluid = water, water and ambiant temperatures = 20 °C, upstream and
downstream distances respected, appropriate pipe dimensions.
6.3.3. Electrical data
Power supply
• version with 2 or 3 outputs (2 wires)
• version with 4 outputs (3 wires)
14-36 V DC, filtered and regulated
12-36 V DC, filtered and regulated
English
Type 8026- 8036- 8076