Instruction Manual
26
Installation and wiring
SE36
S030
1
2
3
SE36
S070
1
2
 → 1: Insert the electronic module in the sensor holder.
 → 2: Turn the electronic module by a quarter turn.
 → 3: Secure the electronic module and the S030 fitting only, by 
tightening the screw with a suitable tool to a max. tightening 
torque of 1 Nm.
Figure 13 :  Assembling the SE36 and the fitting S030 or S070
A
B
 → Check that there is a seal on the fitting and that it is not 
damaged. Replace the seal if necessary.
 → Place nut A on the fitting and insert circlip B into the groove.
 → Carefully insert the device into the fitting. If assembly is 
correct, the device can no longer rotate on itself.
 → Secure the unit with nut A, tightening only by hand.
Figure 14 :  Installation of flowmeter 8026 into the fitting S020
 → Set the K factor parameter (see chap. 9.13.5) or have it determined through a teach-in procedure.
8.2.2.  Recommendations on installing an 8076 on a pipe
 →
Install the fitting S070 on the pipe in such a way that the oval gear axes are in the horizontal plane, as shown 
in Figure 15.
English
Type 8026- 8036- 8076