Manual

l Product speed: slow lling and emptying
l Process/measurement conditions:
- Condensation
- Smooth product surface
- Max. requirement to the measurement accuracy
Storage tanke with product circulation:
l Setup: large-volumed, upright cylindrical, spherical
l Product speed: slow lling and emptying
l Vessel: small laterally mounted or large top mounted stirrer
l Process/measurement conditions:
- Relatively smooth product surface
- Max. requirement to the measurement accuracy
- Condensation
- Slight foam generation
- Overlling possible
Storage tank on ships (Cargo Tank):
l Product speed: slow lling and emptying
l Vessel:
- Installations in the bottom section (bracers, heating spirals)
- High sockets 200 500 mm, also with large diameters
l Process/measurement conditions:
- Condensation, buildup by movement
- Max. requirement on measurement accuracy from 95 %
Stirrer vessel (reactor):
l Setup: all vessel sizes possible
l Product speed:
- Fast to slow lling possible
- Vessel is very often lled and emptied
l Vessel:
- Socket available
- Large agitator blades of metal
- Vortex breakers, heating spirals
l Process/measurement conditions:
- Condensation, buildup by movement
- Strong spout generation
- Very agitated surface, foam generation
Dosing vessel:
l Setup: all vessel sizes possible
l Product speed:
- Fast lling and emptying
- Vessel is very often lled and emptied
l Vessel: narrow installation situation
l Process/measurement conditions:
- Condensation, buildup on the antenna
- Foam generation
LEVEL TRANSMITTER 8136 4 20 mA/HART - two-wire 33
6 Set up with the indicating and adjustment module
41783-EN-120316