Manual

1 Select the menu item "Additional settins" with [->] and conrm with
[OK]. With [->] you have to select the menu item "False signal
suppression" and conrm with [OK].
2 Conrm again with [OK].
3 Conrm again with [OK].
4 Conrm again with [OK] and enter the actual distance from the
sensor to the product surface.
5 All interfering signals in this section are detected by the sensor
and stored after conrming with [OK].
Note:
Check the distance to the product su rface, because if an incorrect (too
large) value is entered, the existing level will be saved as false signal.
The lling level would then no longer be detectable in this area.
If a false signal suppression is already created in the sensor, then the
following menu window appears when selecting "False signal
suppression":
The menu item "Delete" is used to completely delete an already
created false signal suppression. This is useful if the saved false signal
suppression no longer matches the metrological conditions in the
vessel.
LEVEL TRANSMITTER 8136 4 20 mA/HART - two-wire 41
6 Set up with the indicating and adjustment module
41783-EN-120316