Instruction Manual
mxCONTROL Type 8620
Page 51
Datalogging
The datalog file of devices with Ethernet option contains 2 additional columns: “Ethernet state” and
“Ethernet event”.
Ethernet state
Ethernet state Description
-1 Ethernet function disabled
0 Unknown state
1 Ethernet module is initializing / periodically checking network status
5 Ethernet function enabled, but no net link available
9 Disconnecting a connection
10 - 13
Ethernet ready
PC-Tool Access Email notification
10 off off
11 on off
12 off on
13 on on
20 Outgoing connection to mail server
30 Incoming connection (e.g. from PC-Tool)
50 Ethernet module in update mode
Ethernet event
The column “Ethernet event” contains e.g.
• the last displayed ethernet messages (max. 5)
• the email recipients, if emails were successfully sent
• start / end of incoming connection (PC-Tool access)
Configuration (CodeLevel: Specialist)
Configuration
Access
via Cfg.-
menu
Access
via XML-
Cfg.-File
Abbrevia-
tion
(menu)
Value range
Default values
(after factory reset or
at start of Cfg-File-
Download)
Ethernet functionality rw -- Ethernet On, Off On
Remote device access
(via PC-Tool)
rw --
PCTool
Access
On, Off On
Settings (#)
Static IP address rw rw Static IP Yes, No No
Device IP address (*) rw rw IP
0.0.0.0 …
255.255.255.255
0.0.0.0
Subnet mask (*) rW rw SNM
255.0.0.0 …
255.255.255.254
255.255.255.0
Gateway IP address (*) rw rw
Gateway
IP
0.0.0.0 …
255.255.255.255
0.0.0.0
DHCP host name (**) rw rw
DHCP
host name
max. 16 characters
[a-zA-Z0-9_-] -
for default value
leave string empty
ID_SERIAL with
(*****)