9. ASSEMBLY
9.1. Safety instructions
DANGER!
Risk of injury from high pressure in the equipment/device.
Before working on equipment or device, switch off the pressure
and deaerate/drain lines.
Risk of electric shock.
Before reaching into the device, switch off the power supply and
secure to prevent reactivation.
Observe applicable accident prevention and safety regulations for
electrical equipment.
WARNING!
Risk of injury from improper assembly.
Installation must only be carried out by authorized technicians and
with the appropriate tools.
Risk of injury from unintentional activation of the system and
uncontrolled restart.
Secure system against unintentional activation.
Following assembly, ensure a controlled restart.
9.2. Before installation
The FMR can be installed in any position, preferably with the
process controller face up.
To avoid turbulent flows around the pressure sensor, fit an
inlet section upstream of the FMR (dimensions acc. to EN
ISO 5167-1, see “Fig. 5: Inlet sections”, page 10)
Ensure that the pipelines are correctly lined and are not
twisted. If necessary, pipelines must be suitably attached or
supported.
Observe flow direction (arrow on valve body).
9.2.1. Installation
Clean pipelines and joints (sealing material, swarf, etc.).
Connect FMR to pipeline.
9.3. Pneumatic connection of the
process controller
DANGER!
Risk of injury from high pressure in the equipment/device.
Before working on equipment or device, switch off the pressure
and deaerate/drain lines.