User guide
28
Start-up 24 V DC
Typ 8750
11.4. Configuring the F.CONTROL auxiliary
function
→ Add the auxiliary function F.CONTROL to the main menu using
the configuration menu (ADDFUNCTION).
Procedure:
Key Action
MENU
MENU
Press for approx. 3 s
/ Select ADD.FUNCTION
MENU
ENTER
Press
/ Select F.CONTROL
MENU
ENTER
Press
MENU
EXIT
Press
The F.CONTROL function is now activated and incorporated into
the main menu (MAIN).
Tab. 19: Incorporating F.CONTROL into the main menu (MAIN)
→ Enter the basic settings for the flow controller under F.CONTROL.
EXIT
EXIT
PID.PARAM
F.PARAM
DBND 1 %
MTMP
KP 1,00
DENS
TN 999,9
TV 0,0
X0 0,0 %
FILTER 0
F.CONTROL
ENTER ENTER
ENTER
EXIT
EXIT
SETUP
DIAMETER
PV-INPUT
PV-SCALE
SP-INPUT
ENTER
MTMP.INPUT
SP-SCALE
12)
P.CO INIT
VALVE
Fig. 16: Operating structure - basic settings for flow controller
12) The SP SCALE function is indicated only if the external set-
point value default (external) menu option is activated under SP
INPUT.
english