Manual

13
Installation
8. INSTALLATION
8.1. Safety instructions
DANGER!
Risk of injury from high pressure in the equipment!
Before dismounting pneumatic lines or valves, turn off the pres-
sure and vent the lines.
Risk of injury due to electrical shock!
Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation!
Observe applicable accident prevention and safety regulations
for electrical equipment!
WARNING!
Risk of injury from improper installation!
Installation may be carried out by authorized technicians only
and with the appropriate tools!
Risk of injury from unintentional activation of the system and
an uncontrolled restart!
Secure system from unintentional activation.
Following assembly, ensure a controlled restart.
8.2. Installation of the linear Remote
Sensor Type 8798
8.2.1. Attachment to process valves with
internal air supply
(series 2103, 2300 and 2301)
Procedure:
1. Install switch spindle
Transparent hood
Actuator
Control air connections
(plug-in hose connectors with
collets or threaded bushings)
Fig. 7: Installation of linear Remote Sensor, series 2103, 2300 and 2301
Unscrew the transparent hood on the drive and unscrew the
position display (yellow cap) on the spindle extension
(if present).
English
Type 8798