Manual

21
Installation
8.3. Installation of the rotating Remote
Sensor Type 8798
DANGER!
Risk of injury from high pressure in the equipment!
Before dismounting pneumatic lines or valves, turn off the pres-
sure and vent the lines.
Risk of injury due to electrical shock!
Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation!
Observe applicable accident prevention and safety regulations
for electrical equipment!
WARNING!
Risk of injury from improper installation!
Installation may be carried out by authorized technicians only
and with the appropriate tools!
Risk of injury from unintentional activation of the system and
an uncontrolled restart!
Secure system from unintentional activation.
Following assembly, ensure a controlled restart.
8.3.1. Basic installation
Before attaching the rotating sensor to the respective actuator, it is
assembled as described in the following.
Support plate
Rotating
Remote Sensor
Setscrew
Fig. 19: Fit sensor on support plate
Insert the rotating Remote Sensor into the opening of the
support plate until it reaches the stop point.
Attach sensor with the lateral setscrew.
English
Type 8798