Manual

26
Installation
Assemble lever (if not pre-assembled) (see “Fig. 25”).
Depending on the stroke range, a short or long lever is required
for the installation (refer to “Tab. 4”)
Legend:
No. Name
4 Driver pin
5 Conical roller
6 Lever
12
For a description
of the numbering,
refer to “Tab. 4:
Mounting kit to
push actuator for
rotating Remote
Sensor”
13
14
15
16
17
18
19
22
17
16
12
6
19
18
14
12
22
5
4
13
15
Fig. 25: Assembling the lever
The gap between the driver pin and the shaft should be
the same as the actuator stroke. As a result, the lever has a
swivel range of 60°.
Swivel range of the lever:
To ensure that the position sensor operates at a good reso-
lution, the swivel range of the lever must be at least 60°.
60°
Swivel range of the
lever
Fig. 26: Swivel range of the lever
Attach lever to the shaft of the rotating Remote Sensor and
tighten.
Attach mounting bracket with hexagon bolts , circlips
and washers to the support plate of the Remote Sensor
(refer to “Fig. 27”).
To determine the correct position, hold the rotating Remote
Sensor to the actuator.
The conical roller on the lever of the position sensor
must be able to move freely in the hoop (refer to “Fig. 24:
Attaching the hoop”) along the entire stroke range of the
actuator.
At 50% stroke the lever position should be approximately
horizontal (see “Aligning lever mechanism:”, page 28).
English
Type 8798