User guide
26
Technical data
Type S020
6.4.7. K factors (in pulse/l) of the fusion spigots and welding sockets with radius for
measuring devices with a G2'' nut
When the dimensions of the pipe are slightly different from dimensions D and s given in the table, recalculate the K factor using one of
the formulae in chap. 6.4.2.
If the measuring device does not automatically convert the K factor, use the following conversion formulae before setting the para-
meters of the device:
• K factor in pulse/US gallon = K factor in pulse/litre x 3.785
• K factor in pulse/UK gallon = K factor in pulse/litre x 4.546
Table 20: K factors, external diameters and theoretical cross sections of the welding sockets with radius, for measuring devices with a G2''
nut, and of the fusion spigots in plastic, used with a 8020, 8024, 8025 or 8026
Measuring device inserted 8020, 8024, 8025, 8026 External diameters and theoretical cross-sections
Material of the pipe
Stainless
steel
PE / PP PVDF
D
steel
[mm]
s
steel
[mm]
D
PE/PP
[mm]
s
PE/PP
[mm]
D
PVDF
[mm]
s
PVDF
[mm]
DN
50 13,0 (C) - - 60,3 2,0 - - - -
65 7,86 (C) 8,32 (C) 5,53 (C) 76,1 2,9 75 6,9 75 2,5
80 5,52 (C) 5,49 (C) 3,65 (C) 88,9 3,2 90 8,2 90 2,8
100 3,20 (C) 3,51 (C) 2,34 (C) 114,3 3,6 110 10 110 3,5
110 - - - - - - - - -
125 2,00 (C) 2,66 (L) - 139,7 4 140 12,8 - -
150 1,32 (C) 2,12 (L) - 168,3 4,5 160 14,6 - -
180 - - - - - 200 18,2 - -
200 0,72 (C) 0,98 (L) - 219,1 6,3 225 20,5 - -
250 0,50 (L) 0,63 (L) - 273 7,7 280 25,5 - -
300 0,35 (L) 0,42 (L) - 323,9 9,5 315 28,7 - -
350 0,26 (L) 0,30 (L) - 355,6 10,1 355 32,3 - -
400 - 0,23 (L) - - - 400 36,4 - -
English